Product Brochure

7574
INSTALLATION GUIDELINESINSTALLATION GUIDELINES
INSTALLATION INSTRUCTIONS
Please read these instructions completely
before you begin.
adorne
®
switches are designed for installa-
tion in standard electrical boxes. However,
some of the installation methods vary
slightly from traditional methods. If you do
not understand these instructions or are
unsure of your abilities, seek the assis-
tance of a qualified electrician.
Frame
Paddle Switch
Wall Plate
1
3-Way
In a 3-Way circuit, identify
the Common/Hot wire —
connected to the terminal
marked Common or the odd-
colored terminal screw.
Single Pole
WARNING
To prevent severe shock or electrocu-
tion, always disconnect power at the
service panel before beginning work.
When replacing existing switches,
label wires before disconnecting.
Disconnect old switch.
Ground Wire
Common/Hot
Use only with Legrand adorne
®
system.
For more information and helpful
how-to videos, visit
www.adornemyhome.com/install.
Sample Installation: Paddle Switch, 2-Module | Catalog Number: ASPD1532
1-POLE
3-WAY
STRIP GAGE
#14-#12 AWG
15A-120VAC
2
If necessary, cut wires and strip
insulation using stripping guide on
back of switch.
3
Connect frame ground wire to
bare ground wire in box. Fold
ground wires into back of box.
Mount frame to wall box with
screws provided. Tighten screws
just enough to hold frame in
place. Do NOT over-tighten.
TIPS
• Pre-fold wires into wall box
to make it easier to fit them
in the box when switch is
connected.
• Use caution to avoid mar-
ring wall surface with the
metal frame.
WARNING
Failure to connect the
ground wire will result in an
unsafe installation that could
lead to personal injury.