Specification Sheet
8382
WARNING
To prevent severe shock or electrocu-
tion, always disconnect power at the ser-
vice panel before beginning work.
INSTALLATION INSTRUCTIONS
Please read these instructions com-
pletely before you begin. adorne
®
outlets are designed for installa-
tion in standard electrical boxes.
However, some of the installation
methods vary slightly from tradi-
tional methods. If you do not under-
stand these instructions or are
unsure of your abilities, seek the
assistance of a qualified electrician.
1
When replacing existing outlets,
label wires before disconnecting.
Disconnect old outlet.
Split Circuit Tab
Neutral (White)
Hot (Black)
Ground (Bare)
Frame
Outlet
Wall Plate
Ground Wire
For more information and helpful
how-to videos, visit
www.adornemyhome.com/install.
Use only with Legrand adorne
®
system.
HOT
WHITE
2
If necessary,cut wires and strip
insulation using stripping guide on
back of outlet.
3
Connect frame ground wire to
bare ground wire in box. Fold
ground wires into back of box.
Mount frame to wall box with
screws provided. Tighten screws
just enough to hold frame in
place. Do NOT over-tighten.
TIPS
• Pre-fold wires into wall box to
make it easier to fit them in the
box when outlet is connected.
• Use caution to avoid marring
wall surface with the metal frame.
WARNING
Failure to connect the ground
wire will result in an unsafe
installation that could lead to
personal injury.
INSTALLATION GUIDELINESINSTALLATION GUIDELINES
Sample Installation: Tamper-Resistant Outlet | Catalog Number: ARTR152