Owners Manual

Top view audio section inside
1. Sockets for hardwire impedance loads
If you place resistors or capacitors at R102/R202 these parts are directly effective without any activation by a switch. These
parts are always connected in parallel to the 47k input resistor, the 100pF input capacitor and any otherimpedance load
activated by a switch.
2. Sockets for custom load
If you place resistors or capacitors at R104/R204 these parts become effective by activating switch number 3 of sw101/sw201.
These parts are always connected in parallel to the 47k input resistor, the 100pF input capacitor and any other impedance load
activated by a switch or placed in the hardwire sockets R102/R202.
3. Sockets for DC coupling of the outputs
DC Jumpers (and spare jumpers) are supplied. By actiation of these jumpers the output capacitors are bridged. The DC jumpers
are not activated as default.