Leica DISTOTM E7100i The original laser distance meter
Table of Contents EN Instrument Set-up -------------------------Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Insert batteries - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Attach / Remove clip - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 2 2 3 3 3 Operations - - - - - - -
Instrument Set-up Introduction EN Overview The safety instructions and the user manual should be read through carefully before the product is used for the first time. The person responsible for the product must ensure that all users understand these directions and adhere to them. The symbols used have the following meanings: Display WARNING Indicates a potentially hazardous situation or an unintended use which, if not avoided, will result in death or serious injury.
Instrument Set-up Display EN Insert batteries Info i Battery Bluetooth® Area +Main line To ensure a reliable use, do not use zinc-carbon batteries. Change batteries when battery symbol is flashing.
Operations Switching ON/OFF ON EN Clear OFF i 2 sec Device is turned OFF. Press ON button 2 sec to start continuous laser mode. Message Codes 1x Undo last action. 2x If the message "InFo" appears with a number, observe the instructions in "Message Codes" section. Example: Leave actual function, go to default operation mode. Unit setting Switch between the following units: 2 sec 0.000 m 0.0000 m 0.
Measuring Functions Measuring single distance 1 EN 2 i 3 8.532 m Aim active laser at target. Target surfaces: Measuring errors can occur when measuring to colourless liquids, glass, styrofoam or permaeble surfaces or when aiming at high gloss surfaces. Against dark surfaces the measuring time increases. Permanent measuring 1 The last value measured is displayed. 2 3 2 sec Stops permanent measuring. 8.532 m Aim active laser at target. Area 1 2 3 Aim laser at first target point.
Measuring Functions Bluetooth® Smart EN 2 sec I8.462 m2 Value from mainline is transferred Deactivate/Activate Bluetooth® App Mode: Use this mode to transfer the data using an App. i Bluetooth® Smart is always active when the device is switched on. Connect the device with your smart-phone, tablet, laptop,… Measurement values will be transferred automatically right after a measurement. To tranfer a result from the main line, press the Bluetooth® key.
Technical Data EN General Typical Measuring Tolerance* Maximum Measuring Tolerance** Range at Leica target plate GZM26 Typical Range* Range at unfavourable condition **** Smallest unit displayed Power Range Technology™ Laser class Laser type Ø laser point at distances Protection class Autom. laser switch off Autom. power switch-off Bluetooth® Smart Range of Bluetooth® Battery durability (2 x AAA) Dimension (H x D x W) Weight (with batteries) Temperature range: - Storage - Operation ± 1.5 mm / ± 0.
Message Codes Care Warranty If the message Error does not disappear after switching on the device repeatedly, contact the dealer. If the message InFo appears with a number, press the Clear button and observe the following instructions: • Clean the device with a damp, soft cloth. • Never immerse the device in water. • Never use aggressive cleaning agents or solvents. No. Cause Correction 204 Calculation error Perform measurement again.
Safety Instructions The person responsible for the instrument must ensure that all users understand these directions and adhere to them. Symbols used The symbols used have the following meanings: WARNING Indicates a potentially hazardous situation or an unintended use which, if not avoided, will result in death or serious injury.
Safety Instructions Areas of responsibility Responsibilities of the manufacturer of the original equipment: Leica Geosystems AG Heinrich-Wild-Strasse CH-9435 Heerbrugg Internet: www.disto.com The company above is responsible for supplying the product, including the User Manual in a completely safe condition. The company above is not responsible for third party accessories.
Safety Instructions férences pouvant entraîner un fonctionnement non désiré. Ce dispositif est conforme à la norme RSS210 d’Industrie Canada. L’utilisation est sujette aux deux conditions suivantes : • ce dispositif ne pas doit pas être la source d’interférences nuisibles, et • ce dispositif doit accepter toutes les interférences, y compris les interférences pouvant induire des opérations non souhaitées.
Leica Geosystems AG, Heerbrugg, Switzerland has been certified as being equipped with a quality system which meets the International Standards of Quality Management and Quality Systems (ISO standard 9001) and Environmental Management Systems (ISO standard 14001). Total Quality Management - Our commitment to total customer satisfaction. Ask your local Leica Geosystems agent for more information about our TQM program. Copyright Leica Geosystems AG, Heerbrugg, Switzerland 2014 Original text (812795b EN) Pat.