User Manual

Leica DISTO
TM
S910 805080
45
ENMessage Codes
If the message Error does not disappear
after switching on the device repeatedly,
contact the dealer.
If the message InFo appears with a number,
press the Clear button and observe the
following instructions:
Care
Clean the device with a damp, soft cloth.
Never immerse the device in water.
Never use aggressive cleaning agents or
solvents.
Functions
Distance measuring yes
Min/Max measuring yes
Permanent measuring yes
Stake-out yes
Addition/Subtraction yes
Area yes
Triangle area yes
Volume yes
Trapezium yes
Painter function (area with partial
measurem.)
yes
Pythagoras 2-point, 3-point
Smart Horizontal Mode /
Indirect height
yes
Height-profile measurement yes
Level yes
Sloped objects yes
Height tracking yes
Memory yes
Beep yes
Illuminated colour display yes
Pointfinder (Viewscreen) 4x zoom, OV
Bluetooth
®
Smart yes
Personalized Favorites yes
Timer yes
Calculator yes
Photo/Screenshot yes
Compass yes
Gallery with USB download yes
Diameter yes
Width yes
Area from Photo yes
Smart Base yes
Pointdata transmission yes
Point to point function /distance yes
Smart Angle yes
Smart Area yes
DXF Data capture yes
No. Cause Correction
156 Transverse tilt
greater than 10°
Hold the instrument without
any transverse tilt.
162 Calibration mistake Make sure, the device is
placed on a absolutely hori-
zontal and flat surface.
Repeat the calibration
procedure. If the mistake still
occurs, contact your dealer.
204 Calculation error Perform measurement again.
240 Data transfer error Repeat procedure.
252 Temperature too
high
Let device cool down.
253 Temperature too
low
Warm device up.
255 Received signal too
weak, measuring
time too long
Change target surface (e.g.
white paper).
256 Received signal too
high
Change target surface (e.g.
white paper).
No. Cause Correction
258 Measurement outside
of measuring range
Correct range.
260 Laser beam inter-
rupted
Repeat measurement.
300 Smart Base not folded
out
Fold out Smart Base
301 Device was moved,
leveling not valid any
more
Proceed leveling again
302 «Point data transmis-
sion» is selected, but
WiFi is off
Switch on WiFi
340 WiFi: Data transfer
error
Repeat procedure
341 Authentication Error Use correct password