User's Manual
Table Of Contents
- 1 Safety Directions
- 2 Description of the System
- 3 User Interface
- 4 Operation
- 4.1 Equipment Setup
- 4.1.1 Setting up as a Post-Processing Base
- 4.1.2 Fixing the Field Controller to a Holder and Pole
- 4.1.3 Fixing a Hand Strap to the CS
- 4.1.4 Fixing the Utility Hook to the CS
- 4.1.5 Replacing the Display Foil on the CS
- 4.1.6 Inserting and Removing a SIM Card
- 4.1.7 Setting Up for Remote Control or RTK using an Expansion Pack
- 4.1.8 Connecting to a Personal Computer
- 4.1.9 Enabling WLAN in Windows EC7
- 4.2 Batteries
- 4.3 Power Functions
- 4.4 Working with the Memory Device
- 4.5 Using the Digital Camera
- 4.6 Using the Camera Flash Light as Torch
- 4.1 Equipment Setup
- 5 Care and Transport
- 6 Technical Data
- 7 Software Licence Agreement
- Appendix A Pin Assignments and Sockets
A file browser opens. You can now browse within the folders on the
ins
trument.
4.1.9 Enabling WLAN in Windows EC7
☞
By default, the WLAN module is disabled to save battery power.
1. In order to minimise Leic
a Captivate, press Fn and ESC.
2. Select Start\Settings\Network and Dial-Up Connections.
3. In the Network Connections window:
Tap the TIWLNAPI1 icon and select File\Enable.
OR
Hold the stylus on the TIWLNAPI1 icon. Select Enable from the
context menu.
4.2 Batteries
4.2.1 Operating Principles
•
T
he battery must be charged before using it for the first time because it is
delivered with an energy content as low as possible.
•
The permissible temperature range for charging is from 0 °C to +40 °C/
+32 °F to +104 °F. For optimal charging, we recommend charging the bat-
teries at a low ambient temperature of +10 °C to +20 °C/+50 °F to +68 °F
if possible.
•
It is normal for the battery to become warm during charging. Using the
chargers recommended by Leica Geosystems, it is not possible to charge
the battery once the temperature is too high.
•
For new batteries or batteries that have been stored for a long time
(> three months), it is effectual to make only one charge/discharge cycle.
•
For Li-Ion batteries, a single discharging and charging cycle is sufficient. We
recommend carrying out the process when the battery capacity indicated
on the charger or on a Leica Geosystems product deviates significantly
from the actual battery capacity available.
•
T
he batteries can be operated from -30°C to +60°C/-22°F to +140°F.
•
Low operating temperatures reduce the capacity that can be drawn; high
operating temperatures reduce the service life of the battery.