Leica DISTOTM E7500i The original laser distance meter
Table of Contents EN Instrument Set-up -------------------------Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Basic measuring screen - - - - - - - - - - - - - - - - - - - - - - - - - - - Selection screen- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Pointfinder (Viewscreen)- - - - - - - - - - - - - - - - - - - - - - - - - - Insert batteries - - - - - - - - - - - - - - - - -
Instrument Set-up Introduction EN Overview The safety instructions and the user manual should be read through carefully before the product is used for the first time. The person responsible for the product must ensure that all users understand these directions and adhere to them. Display The symbols used have the following meanings: WARNING Indicates a potentially hazardous situation or an unintended use which, if not avoided, will result in death or serious injury.
Instrument Set-up Basic measuring screen Status bar EN Selection screen Page indicator FUNC Function / Settings Main line Active function Favorites Leica DISTOTM E7500i 792324b Settings Help function 3
Instrument Set-up Pointfinder (Viewscreen) EN Insert batteries i Zoom stage 1x Illumination adjustment with navigation keys left and right Active function Crosshair To ensure a reliable use, do not use zinccarbon batteries. We recommend using high quality batteries. Change batteries when battery symbol is flashing.
Operations Switching ON/OFF ON EN Clear OFF i 2 sec 1x If no key is pressed for 180 sec, the device switches off automatically. Device is turned OFF. Message Codes 2x If the info icon appears with a number, observe the instructions in section "Message Codes". Example: Leave actual function, go to default operation mode. Undo last action. Multifunctional endpiece i The orientation of the endpiece is automatically detected and the zero point is accordingly adjusted.
Operations Add / Subtract EN 2x 1 2 7.332 m 3 The next measurement is added to the previous one. The next measurement is subtracted from the previous one. i 4 7.332 m This process can be repeated as required. The same process can be used for adding or subtracting areas or volumes. 20.179 m 12.847 m Pointfinder (Viewscreen) 4x 1x 1 4x 1x 2 3 4 2x 2x 1x i 1x Exit pointfinder (viewscreen). This is a great help for outdoor measuring.
Settings Overview EN Tilt units 1 2 Distance units Beep Digital level Keypad lock Bluethooth® Tilt calibration Favorites Illumination Offset Reset Information Tilt units 1 2 3 Switch between the following units: 360.0° 0.00 % ± 180.0° 0.0 mm/m ± 90.0° 0.00 in/ft Leica DISTOTM E7500i 792324b 4 5 Confirm setting. Exit settings.
Settings Distance units EN Switch between the following units: 1 2 3 0.0000 m 0.000 m 0.00 m 0.0 mm 0.00 ft 0‘00‘‘ 1/32 0‘00‘‘ 1/16 0‘00‘‘ 1/8 0‘00‘‘ 1/4 0.0 in 0 in 1/32 0 in 1/16 0 in 1/8 0 in 1/4 0.000 yd 4 5 Confirm setting. Exit settings. Beep ON/OFF 1 2 3 Exit settings. To switch ON, repeat procedure. OFF ON Digital level ON/OFF 1 2 To switch ON, repeat procedure. ON Leica DISTO TM i 3 The digital level is displayed in the status bar. Exit settings.
Settings De-/Activate keylock 1 EN Switch on with keylock To deactivate, repeat procedure. The keylock is active if device is switched off. 2 3 1 2 within 2 sec Exit settings. ON OFF De-/Activate Bluetooth® Smart 1 2 To switch ON, repeat procedure. ON i i 3 Exit settings. Default mode: Bluetooth® is switched on. Bluetooth® icon in status line is displayed if device is connected with Bluetooth®. OFF Switch on Bluetooth® Smart in Settings.
Settings Calibration of tilt sensor (Tilt Calibration) 1 2 EN 3 4 180° Place device on absolutely flat surface. 180° 5 6 7 Turn the device horizontally by 180° and place it again on absolutely flat surface. 8 Place device on absolutely flat surface. 9 180° 180° 10 i After 2 sec the device goes back to the basic mode. Turn the device horizontally by 180° and place it again on absolutely flat surface.
Settings Personalized favorites EN Favorite 1 2 3 4 Select favorite function. i 5 Press selection key left or right. Function is set as favorite above the corresponding selection key. Select your favorite functions for quick access. Short cut: Press 2 sec on a selection-key in the measuring mode. Exit settings. Illumination 1 2 3 1/6 Leica DISTOTM E7500i 792324b 4 1/6 2/6 3/6 4/6 5/6 6/6 i 5 Confirm setting. Exit settings. To save power reduce brightness if not necessary.
Settings Offset 1 EN 2 3 4 Select digit. i 6 Exit settings. 1.012 m 5 1.012 m Adjust digit. Approve value. An offset adds or subtracts a specified value automatically to or from all measurements. This function allows tolerances to be taken into account. The offset icon is displayed. Reset Second confirmation with selection keys: 1 2 3 Refuse: Confirm: i 4 Reset returns the instrument to the factory settings. All customized settings and memories are lost. Exit settings.
Functions Overview EN Timer Inclination Tracking Measuring on sloped objects Calculator Area Height Tracking Adjusting measuring reference Volume Trapezium Memory Triangle area Stake out Single Distance Measurement Long Range Mode Pythagoras 1 Smart Horizontal Mode Height-profile Measurement Pythagoras 2 Timer 1 2 3 i 4 30 sec 5 sec 2 sec Off Select release time. The self release starts if ON/Measure key is pressed. Confirm setting. Calculator 1 2 Select key on display.
Functions Adjusting measuring reference/tripod 1 2 3 EN Distance is measured from the rear of the device (standard setting). Distance is measured from the front of the device (lock symbol = permanently). Distance is measured from the tripod thread permanently. i 4 If device is switched off, reference goes back to standard setting (rear of the device). If you use an original Leica DISTO adapter, the reference does not need to be adapted to tripod thread! Confirm setting. Memory 1 2 3 12.208 m 6.
Functions Measuring single distance 1 2 EN 3 i 4 8.532 m Aim active laser at target. Target surfaces: Measuring errors can occur when measuring to colourless liquids, glass, styrofoam or semi-permeable surfaces or when aiming at high gloss surfaces. Against dark surfaces the measuring time increases. Smart Horizontal Mode 2 3 4 5.204 m 0.032 m 4.827 m Aim laser at target. x y z x y 40.8 ° 1 z (up to 360° and a transverse tilt of ±10°) Inclination tracking 1 2 3 89.
Functions Area 1 EN 2 3 4 5 Aim laser at first target point. 6.228 m 6 3.9I0 m 20.276 m 24.352 m 2 Leica DISTOTM E7500i 792324b First distance Second distance Circumference Aim laser at second target point. i The result is shown in the main line and the measured value above. Partial Measurements / Painter function: Press + or - before starting the first measurement. Measure and add or subtract distances. Finish with =. Measure 2nd length.
Functions Volume 1 EN 2 3 4 Aim laser at first target point. 5.744 m 8 Second distance 2.431 m Third distance 32.653 m 3 Leica DISTOTM E7500i 792324b 6 7 Aim laser at second target point. First distance 2.338 m 5 9 Use Up/Down navigation keys to show more results. Aim laser at third target point. 2 13.430 m 2 Ceiling/floor area 39.300 m Wall areas 16.
Functions Triangular area 1 EN 2 3 4 5 Aim laser at second target point. Aim laser at first target point. 8 4.248 m First distance 4.129 m Second distance 2.425 m Third distance 4.855 m 2 6 9 Use Up/Down navigation keys to show more results. Switch off Pointfinder if activated. 7 Aim laser at third target point. 33.60° 10.
Functions Height-profile measurement EN 5 1 2 3 4 5 4 3 1 0 REF REF Aim at additional points 1-x. 2x i 7 2.042 m 0.054 m Leica DISTOTM E7500i 792324b d Horizontal distance to device h Height difference to reference point (REF). d 0 Aim at reference point (REF). 6 2 h Exit function. Ideal for measuring of height differences to a reference point. Can be also used to measure profiles and terrain sections.
Functions Sloped objects 1 2 EN 3 4 5 Aim laser at upper target point. 6 11.00 ° 30.367 m -3.440 m 5.452 m i P2 angle P2 distance Vertical height between both points 7 Aim laser at lower target point. Use Up/Down navigation keys to show more results. Switch off Pointfinder if activated. 39.10 ° -4.230 m Included angle between both points Horizontal distance between both points Distance between both points Indirect distance measuring between 2 points with additional results.
Functions Height tracking EN Px Px 1 2 3 4 5 P0 P0 Aim laser at upper points and angle/ height tracking starts automatically. Aim laser at lower point. Px -10.55 ° 29.89 ° 3.475 m P0 x 6.271 m -10.55 ° 7 = Tracking angle if device is turned on tripod y = Tracking height if device is turned on tripod y 6 z Stops height tracking. 6.271 m 44.80 ° 8.478 m P0 8 Use Up/Down navigation keys to show more results. Switch off Pointfinder if activated. Leica DISTOTM E7500i 792324b i 7.
Functions Trapezium 1 EN 2 3 4 Aim laser at upper point. h y 70.80° 5.790 m 7 Use Up/Down navigation keys to show more results. Switch off Pointfinder if activated. Leica DISTOTM E7500i 792324b x h 78.383 m2 20.9 ° y 13.459 m 16.440 m Aim laser at 2nd point.
Functions Stake out i EN Two different distances (a and b) can be entered to mark off defined measured lengths. a= b a= b 1 1 2 3 3 b b b b 4 1.012 m Select digit. 7 8 Approve value "b" and start measurement. Leica DISTOTM E7500i 792324b 2 a a 3 1 2 5 Adjust digit. Move device slowly along the stake-out line. The distance to the next stake out point is displayed. 1.012 m 0.240 m is missing up to next 0.625 m distance. 6 Approve value "a". Next stake out distance 0.625 m 0.
Functions Pythagoras (2-point) 1 2 EN 3 4 5 Aim laser at second target. Aim laser at first target. 6 25.133 m 21.383 m 13.207 m Leica DISTOTM E7500i 792324b i The result is shown in the main line. Pressing the measuring key for 2 sec in the function activates automatically Minimum or Maximum measurement. We recommend to use the pythagoras only for indirect horizontal measuring. For height measuring (vertical) it is more precise to use a function with the inclination measuring.
Functions Pythagoras (3-point) 1 2 EN 3 4 Aim laser at first target. 24.298 m 8 21.264 m 23.018 m 20.571 m Leica DISTOTM E7500i 792324b 5 6 Aim laser at second target. i 7 Aim laser at third target. The result is shown in the main line. Pressing the measuring key for 2 sec in the function activates automatically Minimum or Maximum measurement. We recommend to use the pythagoras only for indirect horizontal measuring.
Technical Data EN Distance measurement Typical Measuring Tolerance* ± 1.0 mm / ~1/16" *** Maximum Measuring Tolerance** ± 2.0 mm / 0.08 in *** Typical Range* 200 m / 660 ft Range at unfavourable condition **** 80 m / 260 ft Smallest unit displayed Power Range Technology 0.1 mm / 1/32 in ™ Ø laser point at distances yes 6 /30 / 60 mm (10 / 50 / 100 m) Tilt measurement Measuring tolerance to laser beam***** ± 0.2° Measuring tolerance to housing***** ± 0.
Message Codes Care Safety Instructions If the message Error does not disappear after switching on the device repeatedly, contact the dealer. If the message InFo appears with a number, press the Clear button and observe the following instructions: • Clean the device with a damp, soft cloth. • Never immerse the device in water. • Never use aggressive cleaning agents or solvents. The person responsible for the instrument must ensure that all users understand these directions and adhere to them.
Safety Instructions EN Permitted use Hazards in use Disposal • Measuring distances • Tilt measurement • Data transfer with Bluetooth® WARNING CAUTION Prohibited use • Using the product without instruction • Using outside the stated limits • Deactivation of safety systems and removal of explanatory and hazard labels • Opening of the equipment by using tools (screwdrivers, etc.
Safety Instructions FCC statement (applicable in U.S.) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Safety Instructions Laser classification EN Description Value Wavelength 620 - 690 nm Maximum radiant output power for classification < 1mW Pulse repetition frequency 320 MHz The device produces visible laser beams, which are emitted from the instrument: It is a Class 2 laser product in accordance with: • IEC60825-1 : 2014„Radiation safety of laser products“ Laser Class 2 products: Do not stare into the laser beam or direct it towards other people unnecessarily.
Leica Geosystems AG, Heerbrugg, Switzerland has been certified as being equipped with a quality system which meets the International Standards of Quality Management and Quality Systems (ISO standard 9001) and Environmental Management Systems (ISO standard 14001). Total Quality Management - Our commitment to total customer satisfaction. Ask your local Leica Geosystems agent for more information about our TQM program. Copyright Leica Geosystems AG, Heerbrugg, Switzerland 2015 Original text (792324b EN) Pat.