Grade mode screen
3.3 Grade Entry
Entering grade
Enter your desired grade in Grade mode. The
Rugby 670/680 will check the level position
and then adjust the plane of laser light to the
grade input.
In Grade mode, the Rugby 670/680 does not
self-level, but is set to detect bumps and
temperature changes.
A small icon in the bottom left corner of the
screen indicates that the axis with grade is
not self-levelling.
Rugby 670
Rugby 680
006057_001
006056_001
The Rugby 670/680 always starts up with no
grade input.
To enter grade, do the following:
1) Press the Grade button once to enter
Grade mode.
2) Press the Up and Down arrow buttons to
enter a grade for the X-axis.
3) Rugby 680 only: Press the Grade button a
second time to switch to the Y-axis.
4) Rugby 680 only: Press the Up and Down
arrow buttons to enter a grade for the Y-
axis.
5) Press the Grade button again to return to
the Main user screen.
The Rugby will begin the grade setting
process.
The smallest grade increment is 0.05%
up to 3.00% grade and 0.10% for
grade greater than 3.00%.
When entering grade the displays
change as shown.
To restore the last set grade(s), press
and hold the Grade button for
1.5 seconds.
If after eight seconds no button is
pressed, the Rugby will accept the
grade entered and will begin the grade
setting process.
Rugby 670: X-axis entry
Rugby 680: X-axis entry
Rugby 680: Y-axis entry
006043_001
006041_001
006042_001