Operation Manual
Rugby 670/680, Operation
22
Bump Alert
Smart Slope
The Bump Alert function prevents incorrect
work caused by movement or settling of the
tripod that occurs when the Rugby is used for
grade.
The Bump Alert function becomes active and
monitors the movement of the Rugby when it
has completely levelled and the head starts
rotating.
If the Rugby gets disturbed, the Bump Alert
screen is displayed and the Rugby beeps
rapidly.
To stop the alert, do one of the following:
• If the height has not changed, press the
Grade button for 1.5 seconds to stop the
alert and continue working.
The Rugby will check level and return to
desired grade.
• If the height has changed, turn the Rugby
off and on again, check the height of the
laser and reenter the grade.
If one axis is still set to Level mode
(0.00%), the Elevation (H.I.) Alert
function is also active for this axis.
The Bump Alert function turns on
automatically every time grade is
entered in the Rugby. It can be
enabled/disabled in the Option Menu
(enabled by default).
The Bump Alert function can be set to
FINE or COARSE in the Option Menu
(COARSE by default).
Bump Alert screen
006046_001
If the Rugby detects a change in ambient
temperature, the grade mechanism will return
to level position, check level and return to the
grade set.
During this, the Rugby cannot be used and
the Smart Slope screen is displayed.
There are two settings for the Smart Slope
function:
• FINE: 2°C temperature change
• COARSE: 5°C temperature change
The Smart Slope setting can be
changed in the Option Menu (COARSE
by default).
Smart Slope screen: COARSE
006048_001