Operation Manual

Rugby 670/680, Accuracy Adjustment
35
7 Accuracy Adjustment
About It is the responsibility of the user to follow operating instructions and to periodi-
cally check the accuracy of the laser and work as it progresses.
The Rugby is adjusted to the defined accuracy specification at the factory. It is
recommended to check the laser for accuracy upon receipt and periodically there-
after to ensure accuracy is maintained. If the laser requires adjustment, contact
your nearest authorised service centre or adjust the laser using the procedures
described in this chapter.
Only enter the accuracy adjustment mode when you plan to change the accuracy.
Accuracy adjustments should only be performed by a qualified individual that
understands basic adjustment principles.
It is recommended to perform this procedure with two people on a relatively flat
surface.
7.1 Checking the Level Accuracy
Checking the level
accuracy
step-by-step
Step Description
1. Place the Rugby on a flat, level surface or tripod approximately 30 m (100 ft)
from a wall.
2. Align the first axis so that it is square to a wall. Allow the Rugby to self-level
completely (approximately 1 minute after the Rugby begins to rotate).
3. Mark the position of the beam.
4. Rotate the laser 180° and allow it to self-level.
5. Mark the opposite side of the first axis.
005772_001
30 m (100 ft)
30 m (100 ft)
X+
X—
005773_001
30 m (100 ft)
30 m (100 ft)
Y+
Y—