Operation Manual

Rugby 670/680, Accuracy Adjustment
36
The Rugby is within its accuracy specification if the four marks are within
± 1.5 mm (± 1/16") from the centre.
7.2 Adjusting the Level Accuracy
Description
Entering Calibra-
tion mode
step-by-step
In Calibration mode, the LED does not blink and the laser head continues to
rotate. An hour-glass indicates that the Rugby is levelling.
6. Align the second axis of the Rugby by rotating it 90° so that this axis is
square to the wall. Allow the Rugby to self-level completely.
7. Mark the position of the beam.
8. Rotate the laser 180° and allow it to self-level.
9. Mark the opposite side of the second axis.
Step Description
In Calibration mode the X-axis calibration screen indicates changes to the X-axis.
The Y-axis calibration screen indicates changes to the Y-axis.
005774_001
X
005775_001
Y
Step Description
1. Turn off the power.
2. Put the Rugby in an upright position.
3. Press and hold both the Up and Down Arrow buttons.
4. Press the Power button. The X-axis calibration screen appears. The Rugby is
now in Calibration mode.