Operation Manual

Rugby 670/680, Accuracy Adjustment
37
Calibrating the
X-axis step-by-step
Upon entering Calibration mode, the X-axis calibration screen appears:
Calibrating the
Y-axis step-by-step
After calibration of the X-axis, the Y-axis calibration screen appears:
Exiting Calibration
mode
Press and hold the Grade button for 3 seconds to save and exit Calibration mode.
Pressing the Power button at any time while in Calibration mode will exit the mode
without saving changes.
Step Description
1. When the hour glass has disappeared, indicating that the Rugby has levelled,
check both sides of the X-axis.
2. Press the Up and Down arrow buttons to bring the plane of laser light to the
specified level position.
Each step represents approximately 2 arc seconds of change. There-
fore, 5 steps equal approximately 1.5 mm at 30 m (1/16" at 100’).
3. Press the Grade button to accept the adjusted position and to switch to the
Y-axis calibration screen.
006059_001
Step Description
1. When the hour glass has disappeared, indicating that the Rugby has levelled,
check both sides of the Y-axis.
2. Press the Up and Down arrow buttons to bring the plane of laser light to the
specified level position.
Each step represents approximately 2 arc seconds of change. There-
fore, 5 steps equal approximately 1.5 mm at 30 m (1/16" at 100’).
3. Press the Grade button to accept the adjusted position and to switch to the
X-axis calibration screen.
4. Press and hold the Grade button for 3 seconds to accept the adjusted posi-
tions, save and store the calibration settings and return to the Main User
screen.
006060_001