10. Click Close Cal and click OK at Verify the cal target is in place. Wait for completion (green check
by Closed cal).
11. Remove the calibration beam from the scanner.
12. Click Open Cal. Then click on OK at Verify the scanner is empty. Wait for completion (green check
by Open cal).
13. Click Clutter cal .
14. Once the clutter cal completes a second window appears and prompts you to review of the test results.
15. Review the results for any failure. Both ISU0 and ISU1 needs reviewed before the system will allow
the baseline to be saved.
16. After reviewing the test results click save baseline, this is only allowable after the test results have be
reviewed and are passing.
17. Once complete close all programs on the Field Service Laptop and disconnect it from the system, then
power off the system.
18. Remove the floor center panel and retain hardware for use later.
3.20.XXX
1. Rotate the swing arm by hand from one bump stop to the other bump stop (for example, across the
full range of travel) to verify that there are no obstructions and that no cables get snagged.
2. Remove the motor brake release jumper.
3. Connect the power cord to the power input box and to an ordinary wall outlet or other power source.
4. Install the floor center panel [1000-11902-00] so that the feet are facing the posing figure on the outer
radome; secure loosely with four M8 x 25mm SHC screws (0201-10018-25) to keep it in place.
Figure 67: Floor Center Panel