Installation Manual

ProVision 3 Installation Manual
8100-35521-00
Rev. A1
Leidos Security Detection & Automation, Inc. Proprietary Page 70 of 119
© 2020 Leidos. All rights reserved
11.30 Blank Plate and Cable Pass-Through Hole
1. Attach the blank plate (3000-23667-00) to the lower hole of the middle OCP cover (3000-27080-00)
if located on right side of electrical enclosure end or upper hole if located on the left side of the
electrical enclosure, as shown in the following figure left, using four M3 flat washers (410-14123)
and four M3 lock nuts (0216-10012-00).
2. Attach the cover plate with 1½-in. [38.1mm] circular hole (3000-23666-00) to the upper hole of the
middle OCP cover if located on right side of electrical enclosure end or lower hole if located on the
left side of the electrical enclosure, as shown in the following figure left, using four M3 flat washers
(410-14123) and four M3 lock nuts (0216-10012-00).
3. Pass the OCP power cord, video graphics array (VGA) cable, touchscreen USB cable, data/reports
universal serial bus (USB) cable, and field service laptop Ethernet cable through the hole, as shown in
the following figure.
4. Install the large rubber grommet (0235-20349-00) to the cable pass-through hole, as shown in the
following figure right. Modify grommet if necessary to fit the hole.
Figure 75: Blank Plate and Cable Pass-Through Hole