Installation Manual

ProVision 3 Installation Manual
8100-35521-00
Rev. A1
Leidos Security Detection & Automation, Inc. Proprietary Page 80 of 119
© 2020 Leidos. All rights reserved
11.47 Entrance/Exit Ramp Supports and Ramp
1. Install the first of two ramp supports [3000-22249-00] at either end of the scanner, as shown in the
following figure.
2. The ramp support is secured with four M10 x 25 FHC screws [0201-20444-25] as shown circled in
green in the following figure.
Figure 88: Ramp Support
3. Repeat steps 1 and 2 for the other ramp support at the opposite end of the scanner.
4. Install the bolt covers 3000-26607-00 and 3000-26607-01 onto the ramps using 3 (0200-28484-08)
SCR, KA35 X 8, TFPH, Z/CLR per cover included with the covers.
Figure 89: Bolt Cover
5. Install the first of two ramps (1000-26611-00) at either end of the scanner, as shown in the following
figure.