22.0 Appendix B: End Cap Notch Delete Plate Installation Procedure
23.0 Purpose
This appendix explains the process to install the end cap notch delete panels (3000-25159-00 or 3000-
24159-001) on to the Provision 3 system.
24.0 Scope
The ProVision 3 end cap panels have a notch to allow the OCP to be mounted on any leg. When the OCP
is not mounted on that leg, the end cap delete panel should be employed.
25.0 Applicable Documents
8100-24685-00 - Installation Manual
26.0 Definitions
OCP = Operator Control Panel
27.0 Requirements
1600-25160-00 KIT, PLATE, NOTCH DELETE, END CAP, GRY, PV2 or
1600-25160-001 KIT, PLATE, NOTCH DELETE, END CAP, WHT, PV2
28.0 Responsibilities
This procedure is used by Leidos field service technicians.