User's Manual

RTR-4 Operator’s Manual System Operation
120300 Rev. D SAIC Proprietary 4-57
Operator Maintenance
RTR-4 owners, custodians and operators may perform limited
maintenance activities as indicated in this section. Contact
technical support as indicated in Chapter 1 for any required
maintenance beyond that is listed here. Refer to the Golden
Engineering XR200 X-ray source Operator’s Manual for X-ray
source care, maintenance and troubleshooting.
RTR-4 Care and Cleaning
The RTR-4 should be stored and transported in the transport case
provided with the equipment. The RTR-4 has no special periodic
maintenance requirements other than battery charging and
routine image quality checking. The RTR-4 external surfaces may
be cleaned carefully using a damp cloth and mild detergent, but
care must be taken to prevent water from seeping inside any of
7 At the X-ray source, turn the keyswitch
counterclockwise 90° to the off position.
8b At the imager, disconnect the communications and
X-ray source cables.
9b Coil up the communications cable and the extension
cable, if used onto the cable reel(s). Use care to avoid
dragging the connector on the ground.
10b Place the communications cable reels into the
transport case ensuring that the knob is in the pocket
provided and the handle is folded to the stowed
position.
11b Disconnect the X-ray source cable from the X-ray
source.
12b Coil the X-ray source cable and place it into the
transport case.
13 Remove the key from the X-ray source keyswitch and
place the source and key into the transport case.
14a Unscrew ANT1 and ANT2 from the imager radio
unit and place the imager and the antennas into the
transport case.
14b Place the imager into the transportation case.