Current Transducer AP-B10
Isolation characteristics
V
b
Rated isolation voltage rms
1)
300 V
with IEC 61010-1 standards and following conditions :
- Reinforced isolation
- Over voltage category CAT III
- Pollution degree PD2
- Heterogeneous field
V
d
Rms voltage for AC isolation test
2)
, 50 Hz, 1min 5 kV
V
e
Partial discharge extinction voltage rms @ 10 pC 1.5 kV
V
w
Impulse withstand voltage 1.2/50 ยตs 6.1 kV
dCp Creepage distance 5.5 mm
dCl Clearance distance 5.5 mm
CTI Comparative tracking index (Group I) 600
Notes :
1)
If insulated cable is used for the primary circuit, the voltage category could
be improved according to the insulation characteristics given by the cable
manufacturer.
e.g.
Cable insulation (primary) Category
HAR 05 600V CAT III
HAR 07 1000V CAT III
2)
Between primary (completely filling the aperture) and secondary.