Datasheet

30.5 x 40.5
70
90
78
12 12
= == =
1
4
Molex 5045-04A
Positive current flow
1
6
30.5 x 40.5
4 3 2 1
Molex 5045-04A
HAT 200-S
30.5 x 40.5
70
90
78
12 12
= == =
HAT-S SERIES
1
4
Pins arrangement:
1 2 3 4
(+) (-) Output 0V
Fixation by base-plate or on bus bar
with M4 screws
All holes O 4.5mm
Molex 5045-04A
99/05
Positive current flow
1
6
30.5 x 40.5
4 3 2 1
Molex 5045-04A
HAT 500-S to 1500-S
HAT 200-S
(unit = mm)
5
12
24
29
38
46 Max
.
15.5
10
30
65
Mechanical characteristics
General tolerance ± 1 mm
Transducer fastening By base-plate or on
bus bar with M4
screws.
All slots 4.5 mm
Connection of secondary Molex 5045-04A
Remarks
I
S
is positive when I
P
flows in the direction of the arrow.
Temperature of the primary conductor should not exceed
100°C.
Dimensions HAT 200..1500-S (in mm. 1 mm = 0.0394 inch)
Front view
Top view
10
Pins arrangement
1 2 3 4
(+) (-) Output 0V
Safety
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
061128/10 www.lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 3/3