Datasheet

Page 1/3
31October2011/version 8 LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice www.lem.com
Current Transducer LF 205-S/SP3
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit and the secondary
circuit.
Electrical data
I
PN
Primary nominal current rms 100 A
I
PM
Primary current, measuring range 0 .. ± 200 A
R
M
Measuring resistance @ T
A
= 70°C T
A
= 85°C
R
M min
R
M max
R
M min
R
M max
with ± 12 V @ ± 100 A
max
0 95 15 94
@ ± 200 A
max
0 40 15 39
with ± 15 V @ ± 100 A
max
16 123 47 122
@ ± 200 A
max
16 55 47 54
I
SN
Secondary nominal current rms 100 mA
K
N
Conversion ratio 1 : 1000
V
C
Supply voltage (+ 5 %) ± 12 .. 15 V
I
C
Current consumption @ ± 15 V 17 + I
S
mA
Accuracy - Dynamic performance data
X
G
Overall accuracy @ I
PN
, T
A
= 25°C ± 0.5 %
ε
L
Linearity error < 0.1 %
Typ Max
I
O
Offset current @ I
P
= 0, T
A
= 25°C ± 0.2 mA
I
OM
Magnetic offset current
1)
@ I
P
= 0 and specied R
M
,
after an overload of 3 x I
PN
± 0.1 mA
I
OT
Temperature variation of I
O
- 40°C .. + 85°C ± 0.25 ± 0.65 mA
t
ra
Reaction time to 10 % of I
PN
step < 500 ns
t
r
Response time
2)
to 90 % of I
PN
step < 1 µs
di/dt di/dt accurately followed > 100 A/µs
BW Frequency bandwidth (- 3 dB) DC .. 100 kHz
General data
T
A
Ambient operating temperature - 40 .. + 85 °C
T
S
Ambient storage temperature - 40 .. + 90 °C
R
S
Secondary coil resistance @ T
A
= 70°C 10
 @ T
A
= 85°C 11
m Mass 78 g
Standards EN 50178: 1997
Notes:
1)
The result of the coercive force (Hc) of the magnetic circuit
2)
With a di/dt of 100 A/µs.
I
PN
= 100 A
Features
Closed loop (compensated)
current transducer using the Hall
effect
Isolated plastic case recognized
according to UL 94-V0.
Special features
I
PN
= 100 A
I
PM
= 0 .. ± 200 A
K
N
= 1 : 1000.
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and
servo motor drives
Static converters for DC motor
drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Application domain
Industrial.
16144