Electrical data
I
PN
Primary nominal r.m.s. current 300 A
I
P
Primary current, measuring range 0 .. ± 500 A
R
M
Measuring resistance R
M min
R
M max
with ± 12 V @ ± 300 A
max
0 37
@ ± 500 A
max
0 8
with ± 15 V @ ± 300 A
max
10 56
@ ± 500 A
max
10 20
I
SN
Secondary nominal r.m.s. current 150 mA
K
N
Conversion ratio 1 : 2000
V
C
Supply voltage (± 5 %) ± 12 .. 15 V
I
C
Current consumption 20 (@ ± 15 V) + I
S
mA
Accuracy - Dynamic performance data
X
G
Overall accuracy @ I
PN
, T
A
= 25°C ± 0.4 %
ε
L
Linearity error < 0.1 %
Typ Max
I
O
Offset current @ I
P
= 0, T
A
= 25°C ± 0.20 mA
I
OM
Residual current
1)
@ I
P
= 0, after an overload of 3 x I
PN
± 0.08 mA
I
OT
Thermal drift of I
O
- 25°C .. + 70°C ± 0.20 ± 0.64 mA
t
ra
Reaction time @ 10 % of I
P max
< 500 ns
t
r
Response time
2)
@ 90 % of I
PN
< 1 µs
di/dt di/dt accurately followed > 100 A/µs
f Frequency bandwidth (- 1 dB) DC .. 100 kHz
General data
T
A
Ambient operating temperature - 25 .. + 70 °C
T
S
Ambient storage temperature - 40 .. + 90 °C
R
S
Secondary coil resistance @ T
A
= 70°C 34
m Mass 60 g
Standards EN 50178 : 1997
Notes :
1)
The result of the coercive field of the magnetic circuit
2)
With a di/dt of 100 A/µs.
Features
Closed loop (compensated) current
transducer using the Hall effect
Insulated plastic case recognized
according to UL 94-V0.
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Application Domain
Industrial.
I
PN
= 300
A
16130