Datasheet

LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM www.lem.com
page 1/3
051123/8
Current Transducer LTSR 15-NP
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Electrical data
I
PN
Primary nominal r.m.s. current 15 At
I
P
Primary current, measuring range 0 .. ± 48
1)
At
V
OUT
Analog output voltage @ I
P
2.5
±
(0.625·I
P
/I
PN
)V
I
P
= 0 2.5
2)
V
V
REF
Voltage reference (internal reference), refout mode 2.5
3)
V
Voltage reference (external reference), refin mode 1.9 .. 2.7
4)
V
N
S
Number of secondary turns 0.1 %) 2000
R
L
Load resistance 2 k
C
L
Max. capacitive loading 500 pF
R
IM
Internal measuring resistance 0.5 %) 83.33
TCR
IM
Thermal drift of R
IM
< 50 ppm/K
V
C
Supply voltage (± 5 %) 5 V
I
C
Current consumption @ V
C
= 5 V Typ 28
+
I
S
5)
+
(V
OUT
/R
L
) mA
Accuracy - Dynamic performance data
X Accuracy @ I
PN
, T
A
= 25°C ± 0.2 %
Accuracy with R
IM
@ I
PN
, T
A
= 25°C ± 0.7 %
ε
L
Linearity error < 0.1 %
Max
TCV
OUT
Thermal drift of V
OUT
/V
REF
@ I
P
= 0
- 40°C .. + 85°C 64 ppm/K
TCε
G
Thermal drift of the gain - 40°C .. + 85°C 50
6)
ppm/K
V
OM
Residual voltage
@ I
P
= 0, after an overload of 3 x I
PN
± 0.5 mV
5 x I
PN
± 2.0 mV
10 x I
PN
± 2.0 mV
TCV
REF
Thermal drift of internal V
REF
@ I
P
= 0 - 10°C .. + 85°C 50 ppm/K
- 40°C .. - 10°C 100 ppm/K
t
ra
Reaction time @ 10 % of I
PN
< 100 ns
t
r
Response time @ 90 % of I
PN
< 400 ns
di/dt di/dt accurately followed > 35 A/µs
f Frequency bandwidth (0 .. - 0.5 dB) DC .. 100 kHz
(- 0.5 .. 1 dB) DC .. 200 kHz
General data
T
A
Ambient operating temperature - 40 .. + 85 °C
T
S
Ambient storage temperature - 40 .. + 100 °C
Insulating material group III a
m Mass 10 g
Standards EN 50178 : 1997
IEC 60950-1 : 2001
Features
Closed loop (compensated) multi-
range current transducer using the
Hall effect
Unipolar voltage supply
Insulated plastic case recognized
according to UL 94-V0
Compact design for PCB mounting
Incorporated measuring resistance
Extended measuring range
Access to the internal voltage
reference
Possibility to feed the transducer
reference from external supply.
Advantages
Excellent accuracy
Very good linearity
Very low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding
applications.
I
PN
=
15 A
Copyright protected.
Application Domain
Industrial.

Summary of content (3 pages)