Datasheet

76 www.lemo.com
®
®
11 34 23.0 8
13 42 28.0 9
16 52 36.0 12
19 61 41.0 15
25 71 50.5 19
38 92 67.0 32
47 118 89.0 38
11 34 23.0 7
13 42 28.0 9
16 52 36.0 12
19 60 40.0 15
25 71 50.5 19
13 14.5 55 41 12 12
16 17.0 65 49 15 15
19 22.0 80 60 19 19
25 36.0 105 84 30 32
~M
~L
ø A
S 2
FFA
Straight plug, cable collet
Reference
Model Series
Dimensions (mm)
ALMS2
S 2
~M
~L
ø A
S 1
ø B
FFA
Reference
Model Series
Dimensions (mm)
A B L M S1 S2
~M
~L
ø A
S 2
FFA Straight plug, cable collet
and nut for fitting a bend relief
1)
Reference
Model Series
Note:
1)
to order, add a «Z» at the end of the reference.
The bend relief must be ordered separately (see page 141).
Dimensions (mm)
ALMS2
FFA 0E
FFA 1E
FFA 2E
FFA 3E
FFA 4E
FFA 5E
FGG
1)
6E
FFA 1E
FFA 2E
FFA 3E
FFA 4E
FFA 0E
FFA 1E
FFA 2E
FFA 3E
FFA 4E
Note:
1)
with key (G)
Technical Characteristics
Electrical
at 10 MHz
at 1 GHz
Characteristics
> 95 dB IEC 60169-1-3
> 80 dB IEC 60169-1-3
Value Standard
Shielding
efficiency
Note: the various tests have been carried out with FFA and ERA con-
nector pairs, with chrome-plated brass shell, PEEK insulator and silicone
O-ring. Detailed electrical characteristics, as well as materials and treatment
are presented in the chapter Technical Characteristics on page 171.
1)
minimum operating temperature is -20°C for sockets fitted with an FPM
(Viton
®
) O-ring.
2)
IP68 achieved providing that the cable is perfectly circular and that
assembly process ensures a high integrity seal.
> 5000 cycles IEC 60512-5 test 9a
up to 95% at 60° C
- 55° C, +200° C
10-2000 Hz, 15 g IEC 60512-4 test 6d
100 g, 6 ms IEC 60512-4 test 6c
> 144h IEC 60512-6 test 11f
IP 68/IP 66 IEC 60529
50/175/21 IEC 60068-1
Endurance
Humidity
Temperature range
1)
Resistance to vibrations
Shock resistance
Salt spray corrosion test
Protection index (mated)
2)
Climatical category
Characteristics Value Standard
Mechanical and Climatical
Metal housing models
Straight plug with oversize cable collet
1)
Note:
1)
correspond to K type of collet, the fitting of oversize collets onto this
model allows them to be fitted to the cables that can be accommodated by
the next housing size up (see page 105).
M2
Cable assembly (pages 167 and 169)
M1
Cable assembly
(pages 167 and 168)
M1
Cable assembly
(pages 167 and 168)