Datasheet

17www.lemo.com
®®
ø A
e
ø B
S 1
N
P
M
L maxi
E maxi
S 2
EEG Fixed socket, nut fixing, key (G) or keys (A…M and R)
(back panel mounting)
Reference
Model Series
EEG 00
EEG 0B
EEG 1B
EEG 2B
EEG 3B
EEG 5B
10 9.5 M7x0.5 2.3 15.5 2.5 13.7 6.0 6.3 7.5
12 12.5 M9x0.6 2.4 20.7 2.5 19.1 6.3 8.2 9.0
16 16.0 M12x1.0 6.5 23.0 3.5 21.1 11.0 10.5 13.0
20 20.0 M15x1.0 3.0 26.7 3.5 24.6 9.0 13.5 15.0
24 25.0 M18x1.0 5.0 30.7 4.5 28.1 12.0 16.5 20.0
41 40.0 M35x1.0 13.5 43.5 5.0 39.6 19.5 33.5 38.0
Dimensions (mm)
AB e E L MN
1)
PS1S2
Note:
1)
maximum length with crimp contacts. The 3B and 5B series are delivered with a
conical nut. The 5B series is delivered without locking washer or tapered washer.
P1
Panel cut-out (page 152)
Reference
Model Series
ECG 00
ECG 0B
ECG 1B
ECG 2B
ECG 3B
ECG 4B
ECG 5B
ø A
e
ø B
S 3
N
M
L maxi
E maxi
S 1
ECG Fixed socket with two nuts, key (G) or keys (A…M and R)
(back panel mounting)
10 10.2 M7x0.5 4.3 13.7 2.5 13.7 6.3 9
12 12.4 M9x0.6 5.5 20.7 2.5 19.1 8.2 11
16 15.8 M12x1.0 6.0 23.0 3.5 21.1 10.5 14
20 19.2 M15x1.0 6.5 26.7 3.5 24.6 13.5 17
24 25.0 M18x1.0 9.0 30.7 4.5 28.1 16.5 22
30 34.0 M25x1.0 10.0 35.7 4.5 32.6 23.5 30
41 40.0 M35x1.0 9.0 43.5 5.0 39.6 33.5
Dimensions (mm)
AB e E LMN
1)
S1 S3
P15
PCB drilling
pattern
(page 154)
Reference
Model Series
ECG 00
ECG 0B
ECG 1B
ECG 2B
ECG 3B
ECG 4B
ECG 5B
ø A
e
ø B
S 3
N
L
M
E maxi
S 1
ECG Fixed socket with two nuts, key (G) or keys (A…F and R)
and straight contact for printed circuit
(back panel mounting)
10 10.2 M7x0.5 4.3 2.5 13.7 6.3 9
12 12.4 M9x0.6 5.5 2.5 16.4 8.2 11
16 15.8 M12x1.0 6.0 3.5 19.8 10.5 14
20 19.2 M15x1.0 6.5 3.5 21.8 13.5 17
24 25.0 M18x1.0 9.0 4.5 25.8 16.5 22
30 34.0 M25x1.0 10.0 4.5 29.8 23.5 30
41 40.0 M35x1.0 9.0 5.0 36.8 33.5
Dimensions (mm)
A B e E M N S1 S3
Note: this contact type is available for E●● socket models fitted with female contacts.
Length «L» depends on the number of contacts, see table on page 156.
The 5B series is delivered with a tapered washer and a round nut.
The 3B, 4B and 5B series are delivered with a conical nut.
Note:
1)
maximum length with crimp contacts. The 3B, 4B and 5B series are delivered
with a conical nut. The 5B series is delivered with a tapered washer and a round nut.
ø A
e
ø B
N
P
M
L maxi
E maxi
S 2
EFG Fixed socket, nut fixing, key (G) or keys (A…M),
with two flats on the shell and O-ring
(back panel mounting)
12 12.5 M9x0.6 5.5 20.7 2.5 19.1 9 8
Reference
Model Series
EFG 0B
Dimensions (mm)
AB e E L MN
1)
PS2
P2
Panel cut-out (page 152)
P1
Panel
cut-out
(page 152)
Note:
1)
maximum length with crimp contacts.
P1
Panel cut-out (page 152)