Datasheet
173www.lemo.com
®
®
Mechanical latching characteristics
F
v
: average latching force.
F
d
: average unmating force with axial pull on
the outer shell.
F
a
: average pull force with axial pull on
the collet nut
Notes: forces were measured on outer shells not fitted with contacts.
Mechanical endurance: 5000 cycles.
Mechanical endurance represents the number of cycles after which the latching system is still effective (1 cycle = 1 latching/unlatching at 300 cycles per
hour). The values were measured according to the standard IEC 60512-7 test 13a.
Fv
Fd
Fa
Force
(N)
Fv
Fd
Fa
Series
00 0S 1D 1S 2C 2S 3S 4S 5S 6S
9 14 14 15 12 17 20 40 60 70
7911 10 12 11 14 25 40 55
120 140 300 250 400 350 500 650 750 900
Standard series
Force
(N)
Fv
Fd
Fa
Force
(N)
Fv
Fd
Fa
Series
0E 0L 1E 1L 2E 2L 3E 4E 5E 6E
14 14 16 16 20 20 32 65 85 100
9910 10 13 13 25 40 60 75
250 250 300 300 400 400 550 700 800 900
Watertight series
Series
00 0B 1B 2B 2G 3B 4B 5B
9 10 14 15 12 17 39 48
7811 12 12 14 38 38
100 180 300 300 400 400 600 800
Keyed series
Force
(N)
Fv
Fd
Fa
Series
0K 1K 2K 3K 4K 5K
14 16 20 32 65 85
9 10 13 25 40 60
250 300 400 550 700 800
Keyed watertight series
The electromagnetic compatibility of a device can only be
ensured by meeting a number of basic rules with the design
of the device and by carefully selecting components, cables
and connectors.
Electrical and electronic devices are to be designed to ensure
the following:
a) reduce the emission of generated electromagnetic
disturbance to a level where radios and telecommunication
and other devices can properly function;
b) electromagnetic immunity against electromagnetic
disturbance so that they can properly function.
When selecting a connector, screen or shielding efficiency
and low resistance to electric continuity between the cable
and the connector should be considered.
The design of LEMO connectors with metal shell and earth-
ing crown guarantee optimum shielding efficiency in all
applications where electromagnetic compatibility (EMC) is
critical.
The performance of a connector is measured through
shielding efficiency, a value that represents the ratio between
the electromagnetic field on the outside and the inside of the
shell. Our measurements are carried out according to the IEC
60169-1-3 standard.
Electromagnetic compatibility (EMC)
and shielding efficiency
10 K
20 K
50 K
100 K
1 M
2 M
5 M
10 M
20 M
50 M
100 M
200 M
500 M
1 G
200 K
500 K
FGG + PHG.1B
-35
-30
-25
-20
-15
-10
-5
0
5
110
100
90
80
70
60
50
40
30
(dBOhm) (dB)
(Hz)
FGG + PHG.1K
The performance of S and B series connectors is compa-
rable to the results of measurements carried out on a pair
of FGG + PHG.1B connectors.
The performance of E and K series connectors is compa-
rable to the results of measurements carried out on a pair
of FGG + PHG.1K connectors.
Transfer impedance
Shielding efficiency
Frequency
Notes: 1N = 0.102 kg.