Blower User Manual

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
1
GENERAL INFORMATION
BLOWER KIT
LBLK-100
This blower kit may be used with ELDV series fireplaces. The LBLK-
100 blower kit is used with a field supplied ON/OFF power switch. The
blower is installed beneath the firebox. Room air is drawn in through
the bottom area of the fireplace, heated as it passes across the
firebox, and discharged through the upper open area at the top of the
fireplace. The LBLK-100 blower kit contains one blower, one power
cord and these instructions.
HEARTH PRODUCTS
KITS AND ACCESSORIES
INSTALLATION INSTRUCTIONS FOR BLOWER KIT
LBLK-100 (CATALOG NO. H4678) FOR USE WITH ELDV SERIES FIREPLACES
Step 1. Turn off the fireplace and allow it to cool before proceeding.
Step 2. If the appliance is connected to 120 volt power, disconnect
the power.
Step 3. Shut off the gas supply to the fireplace.
Step 4. Remove the bottom panel of the fireplace by pulling it forward.
(
see Figure 1
).
Step 5. Remove the door assembly by opening the two latches (located
under the door assembly) securing the glass door (
see Figure 1
).
INSTALLATION INSTRUCTIONS
Figure 1
750,216M
REV. N/C 03/2006
Figure 2
Blower Cover Panel
Burner Baffle
Burner Assembly
Grate Assembly
Logs
Bottom Panel
Door Asembly
Step 6. Remove the logs from the fireplace (
see Figure 1
). Handle logs
carefully to prevent breakage.
Step 7. Remove the grate asembly, burner baffle, burner asembly
(
Figure 2
) and the blower cover panel (
Figure 3
).
Step 8. Connect the provided power cord to the terminals on the blower.
Figure 3
Blower Cover Panel