R E A D A N D SAVE TH E S E I N STR U C TI O N S OWNER’S MANUAL For Models WB2-12, WB2-17 & WP2-18 Includes Safety, Operating, and Maintenance Instructions and Warranty
Lennox Healthy Climate ™ Humidifier ® Table of Contents Page Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Principle of Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Effect of Water Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Annual Maintenance .
your new humidifier can do for you, and what you should do to receive maximum benefits from it. This booklet is intended to answer these questions. The humidifier operates in conjunction with the furnace blower motor. When the humidistat calls for humidity and the blower motor is operating, water flows to the distribution pan located at the top of the unit. The water is uniformly distributed across the width of the pan and through a scientifically designed system of outlets.
II. Operating Instructions Your new Lennox Healthy Climate Humidifier is controlled by a manual humidistat installed either in the living area or in the cold air return. It is important to anticipate a drop in temperature and reduce the setting accordingly to avoid excessive condensation. For example, with an outside temperature of 20° the correct setting will be 35% relative humidity.
IV. Annual Maintenance For best performance, we recommend that you replace the evaporative media in your humidifier annually. • Call the installer of your humidifier. This information is often found on your equipment. V. Annual Summer Shutdown FOR THE SUMMER HUMIDIFIER SHUTDOWN, SIMPLY TURN THE HUMIDISTAT CONTROL TO THE “OFF” SETTING AND CLOSE THE DAMPER IN THE WB2-12 AND WB2-17 MODELS. VI.
MAINTENANCE INSTRUCTIONS FOR LENNOX HEALTHY CLIMATE HUMIDIFIER MODELS WB2-12 & WB2-17 2 3 5 1 1. 2. 3. 4. 5. 6. 4 6 Front Cover Distribution Tray* ”V” Notches Evaporative Media* Scale Control Insert* Drain Hose * Represents the evaporative assembly CAUTION! Sudden operation may cause personal injury or property damage. Turn humidistat to “OFF” or lowest setting before servicing. 1. Note humidistat setting and turn humidistat to the “OFF” position. 2.
MAINTENANCE INSTRUCTIONS FOR LENNOX HEALTHY CLIMATE HUMIDIFIER MODEL WP2-18 5 1 1. 2. 3. 4. 5. 6. 7. 8. 9. Front Cover Base Evaporative Assembly Distribution Tray ”V” Notches Evaporative Media Scale Control Insert Drain Hose Power Cord 3 2 4 6 7 8 9 WARNING! 120 VOLTS may cause serious injury from electrical shock. Disconnect power and shut off water supply before servicing. 1. Note humidistat setting and turn humidistat to the “OFF” position. 2.
LIMITED WARRANTY Your Lennox Healthy Climate Humidifier unit is expressly warranted for one (1) year from date of installation to be free from manufacturing defects except, however, for the disposable evaporative media which will have to be replaced from time to time depending upon the amount of use.