User Guide
Fill the hopper with pellets
Make sure the hopper lid is completely closed
Press the “START” button on the control panel to   
  begin the ignition cycle
1.
2.
3.
Open hopper lid and fill hopper with pellets
Make sure the hopper lid is completely closed
Check to make sure the stove remains lit
If the flame goes out, press the “START” button 
  on the control panel to re-ignite
1.
2.
3.
4.
Press the 
START
HEAT
OUTPUT
BLOWER
FEEDING
STOP
(-) (+)
O
(-) (+)
O
COMBUSTION
AIR
PELLET
FEED
HE AR TH  P RO DU CT S
 “STOP” button 
  (The fans will automatically turn off once the stove 
  has cooled down)
1.
  FLAME APPEARANCE
PROPERLY ADJUSTED FLAME IMPROPERLY ADJUSTED FLAME 
START
HEAT
OUTPUT
BLOWER
FEEDING
STOP
(-) (+)
O
(-) (+)
O
COMBUSTION
AIR
PELLET
FEED
HE ARTH  PRODUCTS
3
The appearance of the flame can be a good indicator of the overall performance of the stove. A bright clean flame 
indicates proper balanced and efficient burning, while a dark slow-moving flame indicates incomplete combustion 
and a stove that may be in need of service and/or adjustment.
  MANUAL OPERATION*
2
START
HEAT
OUTPUT
BLOWER
FEEDING
STOP
(-) (+)
O
(-) (+)
O
COMBUSTION
AIR
PELLET
FEED
HE AR TH  P RO DU CT S
START
HEAT
OUTPUT
BLOWER
FEEDING
STOP
(-) (+)
O
(-) (+)
O
COMBUSTION
AIR
PELLET
FEED
HE AR TH  P RO DU CT S
START
HEAT
OUTPUT
BLOWER
FEEDING
STOP
(-) (+)
O
(-) (+)
O
COMBUSTION
AIR
PELLET
FEED
HE AR TH  P RO DU CT S
Combustion Air Trim Heat Output Button Blower Button
Once the stove is running, you 
can use the heat output button 
to choose between five levels 
ranging from low to high.
The blower button is used to 
vary the output of the room fan. 
Choose between five levels rang-
ing from low to high.
Used to fine tune the amount of 
combustion air to better accom-
modate variables such as venting 
configuration, altitude and fuel.
Pellet Feed Trim
Used to fine tune the amount of 
pellets fed into the UltraGrate™ 
and accommodate variations in 
pellet size.
Hopper lid must 
be closed during 
operation.
The control board is located on the left 
side of the stove.
* Refer to the Manual if you are connecting your stove to a thermostat. Ignition and control board functions for 
automatic (thermostat) operation are different from the explanations given above.
SHARP ACTIVE   
  FLAME 
BRIGHT YELLOW HUE
PELLET EMBERS   
  ACTIVELY MOVE IN   
  THE ULTRAGRATE
•
•
•
SLOW LAZY FLAME
DARK ORANGE HUE
LARGE FLAME WITH   
  BLACK SOOTY TIPS
PELLETS BUILD UP IN   
  THE ULTRAGRATE
•
•
•
•
START
HEAT
OUTPUT
BLOWER
FEEDING
STOP
(-) (+)
O
(-) (+)
O
COMBUSTION
AIR
PELLET
FEED
HE AR TH  P RODUCTS
START
HEAT
OUTPUT
BLOWER
FEEDING
STOP
(-) (+)
O
(-) (+)
O
COMBUSTION
AIR
PELLET
FEED
HE AR TH  P RODUCTS
STARTING THE MONTAGE™ PELLET STOVE
RE-FUELING WHILE IN OPERATION
STOPPING THE MONTAGE PELLET STOVE
START
HEAT
OUTPUT
BLOWER
FEEDING
STOP
(-) (+)
O
(-) (+)
O
COMBUSTION
AIR
PELLET
FEED
HE AR TH  P RO DU CT S
The stove burns clean and heats efficiently.  Requires more frequent maintenance and can be unsafe 
to operate.
Failure to ensure that pellets in the UltraGrate™ remain burning 
after re-fueling may result in smoke escaping from the unit.