User Guide

Page 27
XP13 SERIES
Liquid Pressure
Model
Number
Heating Cooling
ºF (ºC)*
20
(−7)
30
(−1)
40
(4.5)
50
(10)
60
(16)
65
(18)
70
(21)
75
(24)
80
(27)
85
(29)
90
(32)
95
(35)
100
(38)
105
(41)
110
(43)
115
(45)
13HPX−018 275 289 305 323 340 236 252 272 294 316 339 363 389 415 443 472
13HPX−024 267 283 299 316 334 251 271 293 315 337 361 386 413 441 471 502
13HPX−030 267 279 292 305 317 259 283 307 331 355 379 403 427 451 475 499
13HPX−036 289 309 301 335 353 264 284 305 327 350 372 399 425 452 480 510
13HPX−042 275 288 299 313 324 238 258 280 303 325 350 375 402 430 459 490
13HPX−048 274 286 299 309 316 245 265 285 307 330 354 381 409 438 469 505
13HPX−060 275 287 293 326 339 259 272 294 315 343 366 388 416 443 474 494
*Temperature of the air entering the outside coil.
Table 5. HFC−410A Temperature (°F) − Pressure (Psig)
°F °C Psig °F °C Psig
−40 −40.0 11.6 60 15.6 170
−35 −37.2 14.9 65 18.3 185
−30 −34.4 18.5 70 21.1 201
−25 −31.7 22.5 75 23.9 217
−20 −28.9 26.9 80 26.7 235
−15 −26.1 31.7 85 29.4 254
−10 −23.3 36.8 90 32.2 274
−5 −20.6 42.5 95 35.0 295
0 −17.8 48.6 100 37.8 317
5 −15.0 55.2 105 40.6 340
10 −12.2 62.3 110 43.3 365
15 −9.4 70.0 115 46.1 391
20 −6.7 78.3 120 48.9 418
25 −3.9 87.3
125 51.7 446
30 −1.1 96.8 130 54.4 476
35 1.7 107 135 57.2 507
40 4.4 118 140 60.0 539
45 7.2 130
145 62.8 573
50 10.0 142
150 65.6 608
55 12.8 155