5.Connectthepowercordtothepowercordconnectoronthenewhot-swapredundantpowersupply.
Then,checkthestatusLEDnearthepowercordconnector.WhentheLEDislitingreen,itindicates
thatthehot-swapredundantpowersupplyisworkingcorrectly.WhentheLEDislitinamber,it
indicatesthatthehot-swapredundantpowersupplyislikelytofailorhasfailed.Youmightneedto
reinstallorreplaceit.
6.Ifyouareinstructedtoreturntheoldhot-swapredundantpowersupply,followallpackaginginstructions
anduseanypackagingmaterialsthataresuppliedtoyouforshipping.
Installingorreplacingaheatsink
Attention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”
onpageiiiand“Guidelines”onpage69.
Thistopicprovidesinstructionsonhowtoinstallorreplaceaheatsink.
CAUTION:
Theheatsinkmightbeveryhot.Turnofftheserverandwaitthreetoveminutestolettheserver
coolbeforeremovingtheservercover.
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanother
computerforreference.
Note:Dependingonthemodel,yourservermightlookslightlydifferentfromtheillustrationsinthistopic.
Toinstallorreplaceaheatsink,dothefollowing:
1.Removeallmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,disconnectall
powercordsfromelectricaloutletsanddisconnectallcablesthatareconnectedtotheserver.
2.Iftheserverisinstalledinarackcabinet,removetheserverfromtherackcabinetandplaceitonaat,
clean,andstatic-protectivesurface.SeetheRackInstallationInstructionsthatcomeswiththeserver.
3.Removetheservercover.See“Removingtheservercover”onpage71.
4.Removethecoolingshroud.See“Removingandreinstallingthecoolingshroud”onpage76.
5.Locatetheheatsinkortheplaceforinstallingthesecondheatsink.See“Servercomponents”on
page29.