Server User Manual

Whattodonext:
Toworkwithanotherpieceofhardware,gototheappropriatesection.
Tocompletethereplacement,goto“Completingthepartsreplacement”onpage153.
Replacingthediagnosticmodule
Thistopicprovidesinstructionsonhowtoreplacethediagnosticmodule.Fordetailedinformationaboutthe
diagnosticmodule,see“Diagnosticmodule”onpage21.
Thistopiccontainsthefollowingitems:
Replacingthediagnosticmoduleforservermodelswith3.5-inchharddiskdrives
Replacingthediagnosticmoduleforservermodelswith2.5-inchharddiskdrives
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanother
computerforreference.
Note:Dependingonthemodel,yourserveranddiagnosticmodulemightlookslightlydifferentfromthe
illustrationsinthistopic.
Replacingthediagnosticmoduleforservermodelswith3.5-inchharddiskdrives
Attention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”
onpageiiiand“Guidelines”onpage69.
Toreplacethediagnosticmoduleforservermodelswith3.5-inchharddiskdrives,dothefollowing:
1.Removeallmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,disconnectall
powercordsfromelectricaloutletsanddisconnectallcablesthatareconnectedtotheserver.
2.Iftheserverisinstalledinarackcabinet,removetheserverfromtherackcabinetandplaceitonaat,
clean,andstatic-protectivesurface.SeetheRackInstallationInstructionsthatcomeswiththeserver.
3.Removetheservercover.See“Removingtheservercover”onpage71.
4.Locatethediagnosticmodule.See“Servercomponents”onpage29.
5.Disconnectthecablefromtherearofthediagnosticmodule.
146ThinkServerUserGuide