DiagnosticerrorcodeFRU/Action
000-250-XXXBIOSAPMfailure1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage99
2.Systemboard
000-270-XXXBIOSACPIfailure1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage99
2.Systemboard
001-000-XXXSystemtestpassed
Noaction
001-00X-XXXSystemerrorSystemboard
001-01X-XXXSystemerrorSystemboard
001-024-XXXSystemaddressingtestfailureSystemboard
001-025-XXXSystemchecksumvalueerror1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage99
2.Systemboard
001-026-XXXSystemFLASHdataerror1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage99
2.Systemboard
001-027-XXXSystemconguration/setuperror1.RunSetup
2.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage99
3.Systemboard
001-032-XXXSystemdevicecontrollerfailureSystemboard
001-034-XXXSystemdevicebufferallocationfailure
1.Rebootthesystem
2.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage99
3.Runmemorytest
4.Systemboard
001-035-XXXSystemdeviceresetconditiondetectedSystemboard
001-036-XXXSystemregistererrorSystemboard
001-038-XXXSystemextensionfailure
1.Adaptercard
2.Systemboard
001-039-XXXSystemDMIdatastructureerror1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage99
2.Systemboard
001-040-XXXSystemIRQfailure1.Power-off/onsystemandre-test
2.Systemboard
001-041-XXXSystemDMAfailure1.Power-off/onsystemandre-test
2.Systemboard
001-195-XXXSystemtestabortedbyuser
InformationonlyRe-startthetest,ifnecessary
001-196-XXXSystemtesthalt,errorthresholdexceeded
1.PressF3toreviewthelogle
2.Re-startthetesttoresetthelogle
Chapter7.Symptom-to-FRUindex47