User's Manual

Chapter8.InstallingharddiskdrivesandconguringRAID
(types:4155,4158,4218)
ThischaptercontainsinformationaboutinstallingharddiskdrivesandconguringRedundantArrayof
IndependentDisks(RAID)forthisproduct.
Note:TheinformationaboutconguringRAIDinthischapteronlyappliesforaWindowsenvironment.For
informationaboutconguringRAIDinaLinuxenvironment,contactyourLinuxsoftwareprovider.
InstallingSATAorSASharddiskdrivesandconguringRAID
ThissectioncontainsinformationabouttherequirednumberofSATAorSASharddiskdrivesforthe
supportedlevelofRAIDconguration.
Note:YourcomputermusthaveeitherallSATAharddiskdrivesorallSASharddiskdrivesinstalled.
However,besurethatyoudonotinstallboththeSATAandSASharddiskdrivesintothesamecomputer.
InstallingSATAorSASharddiskdrives
YourcomputermusthavetheminimumnumberofSATAorSASharddiskdrivesinstalledforthesupported
levelofRAIDbelow:
RAIDLevel0Stripeddiskarray
Twoharddiskdrivesminimum
Betterperformancewithoutfaulttolerance
RAIDLevel1Mirroreddiskarray
Twoharddiskdrivesminimum
Improvedreadperformanceand100%redundancy
RAIDLevel5Block-levelstripeddiskarraywithdistributedparity
Threeharddiskdrivesminimum
Datastripedatthebytelevel
Stripeerrorcorrectioninformation
Betterperformanceandfaulttolerance
RAIDLevel10CombiningfeaturesofRAID0andRAID1
Fourharddiskdrivesminimum
Veryhighreliabilitycombinedwithhighperformance
Faulttolerance
ToinstallanewSATAorSASharddiskdrive,refertotheinstallationprocedurein“Replacingaharddisk
drive”intheThinkStationHardwareInstallationandReplacementGuide.
EnteringtheMarvellBIOSSetuptocongureSATAorSASRAID
ThissectiondescribeshowtoentertheMarvellBIOSSetuptocongureaSATAorSASRAID.
1.TurnonthecomputerafteryouhaveinstalledtherequirednumberofSATAorSASharddiskdrives.
2.PressCtrl+MwhenpromptedtoentertheMarvellBIOSSetuptocongureSATA/SASRAID.
©CopyrightLenovo2008,2012
49