Computer Hardware User Manual
DiagnosticErrorCodeFRU/Action
086-199-XXXMousePortinterfacetestfailed,cause
unknown
1.See“Undeterminedproblems”onpage71
2.Flashthesystemandre-test.See“Updating
(ashing)theBIOSfromadisc”onpage469
3.Replacecomponentunderfunctiontest
089-000-XXXMicroprocessorTestPassedNoaction
089-XXX-XXXMicroprocessorfailure
1.Microprocessor(s)
2.Systemboard
089-195-XXXMicroprocessorTestabortedbyuser
InformationonlyRe-startthetest,ifnecessary
089-196-XXXMicroprocessortesthalt,errorthreshold
exceeded
1.PressF3toreviewthelogle
2.Re-startthetesttoresetthelogle
089-197-XXXMicroprocessortestwarning1.Makesurethecomponentthatiscalledoutis
connectedand/orenabled.SeeChapter6“Usingthe
SetupUtilityprogram”onpage43
2.Re-runtest
3.Replacethecomponentthatiscalledoutinwarning
statement
4.Replacethecomponentundertest
089-198-XXXMicroprocessortestaborted
1.Flashthesystem.See“Updating(ashing)theBIOS
fromadisc”onpage469
2.Goto“Undeterminedproblems”onpage71
089-199-XXXMicroprocessortestfailed,causeunknown
1.See“Undeterminedproblems”onpage71
2.Flashthesystemandre-test.See“Updating
(ashing)theBIOSfromadisc”onpage469
3.Replacecomponentunderfunctiontest
170-000-XXXVoltageSensor(s)TestPassed
Noaction
170-0XX-XXXVoltageSensor(s)failure
1.Flashsystem
2.Systemboard
170-195-XXXVoltageSensor(s)Testabortedbyuser
InformationonlyRe-startthetest,ifnecessary
170-196-XXXVoltageSensor(s)testhalt,errorthreshold
exceeded
1.PressF3toreviewthelogle
2.Re-startthetesttoresetthelogle
170-197-XXXVoltageSensor(s)testwarning
1.Makesurethecomponentthatiscalledoutis
connectedand/orenabled.SeeChapter6“Usingthe
SetupUtilityprogram”onpage43
2.Re-runtest
3.Replacethecomponentthatiscalledoutinwarning
statement
4.Replacethecomponentundertest
170-198-XXXVoltageSensor(s)testaborted
1.Ifacomponentiscalledout,makesureitis
connectedand/orenabled.SeeChapter6“Usingthe
SetupUtilityprogram”onpage43
2.Flashthesystemandre-test.See“Updating
(ashing)theBIOSfromadisc”onpage469
3.Goto“Undeterminedproblems”onpage71
64ThinkCentreHardwareMaintenanceManual