Computer Hardware User Manual

Table Of Contents
Diagnosticerrorcodes
Refertothefollowingdiagnosticerrorcodeswhenusingthediagnostictests.See"Runningtests"on
page35forthespecictypeforinformationabouttheDiagnosticprograms.
Inthefollowingindex,Xcanrepresentanynumber.
DiagnosticErrorCodeFRU/Action
000-000-XXXBIOSTestPassed
Noaction
000-002-XXXBIOSTimeout1.Flashthesystem.See"Flashupdateprocedures"
onpage467
2.Systemboard
000-024-XXXBIOSAddressingtestfailure1.Flashthesystem.See"Flashupdateprocedures"
onpage467
2.Systemboard
000-025-XXXBIOSChecksumValueerror1.Flashthesystem.See"Flashupdateprocedures"
onpage467
2.Systemboard
000-026-XXXFLASHdataerror1.Flashthesystem.See"Flashupdateprocedures"
onpage467
2.Systemboard
000-027-XXXBIOSConguration/Setuperror1.RunSetup
2.Flashthesystem.See"Flashupdateprocedures"on
page467
3.Systemboard
000-034-XXXBIOSBufferAllocationfailure
1.Rebootthesystem
2.Flashthesystem.See"Flashupdateprocedures"on
page467
3.Runmemorytest
4.Systemboard
000-035-XXXBIOSResetConditiondetected1.Flashthesystem.See"Flashupdateprocedures"
onpage467
2.Systemboard
000-036-XXXBIOSRegistererror1.Flashthesystem.See"Flashupdateprocedures"
onpage467
2.Systemboard
000-038-XXXBIOSExtensionfailure1.Flashthesystem.See"Flashupdateprocedures"
onpage467
2.PCIadaptercard
3.Systemboard
000-039-XXXBIOSDMIdataerror1.Flashthesystem.See"Flashupdateprocedures"
onpage467
2.Systemboard
000-195-XXXBIOSTestabortedbyuser
InformationonlyRe-startthetest,ifnecessary
000-196-XXXBIOStesthalt,errorthresholdexceeded
1.PressF3toreviewthelogle
2.Re-startthetesttoresetthelogle
44ThinkCentreHardwareMaintenanceManual