DiagnosticErrorCodeFRU/Action
001-038-XXXSystemExtensionfailure1.PCIadaptercard
2.Systemboard
001-039-XXXSystemDMIdatastructureerror1.Flashthesystem.See"Flashupdateprocedures"
onpage467
2.Systemboard
001-040-XXXSystemIRQfailure1.Power-off/onsystemandre-test
2.Systemboard
001-041-XXXSystemDMAfailure1.Power-off/onsystemandre-test
2.Systemboard
001-195-XXXSystemTestabortedbyuser
InformationonlyRe-startthetest,ifnecessary
001-196-XXXSystemtesthalt,errorthresholdexceeded
1.PressF3toreviewthelogle
2.Re-startthetesttoresetthelogle
001-197-XXXSystemtestwarning
1.Makesurethecomponentthatiscalledoutis
connectedand/orenabled.SeeChapter6"Using
theSetupUtility"onpage39
2.Re-runtest
3.Replacethecomponentthatiscalledoutinwarning
statement
4.Replacethecomponentundertest
001-198-XXXSystemtestaborted
1.Ifacomponentiscalledout,makesureitis
connectedand/orenabled.SeeChapter6"Using
theSetupUtility"onpage39
2.Flashthesystemandretest.See"Flashupdate
procedures"onpage467
3.Goto"Undeterminedproblems"onpage65
001-199-XXXSystemtestfailed,causeunknown1.Goto"Undeterminedproblems"onpage65
2.Flashthesystemandre-test
3.Replacecomponentunderfunctiontest
001-250-XXXSystemECCerrorSystemboard
001-254-XXX001-255-XXX001-256-XXX001-257-XXX
SystemDMAerror
Systemboard
001-260-XXX001-264-XXXSystemIRQerrorSystemboard
001-268-XXXSystemIRQ1failure1.DeviceonIRQ1
2.Systemboard
001-269-XXXSystemIRQ2failure1.DeviceonIRQ2
2.Systemboard
001-270-XXXSystemIRQ3failure1.DeviceonIRQ3
2.Systemboard
001-271-XXXSystemIRQ4failure1.DeviceonIRQ4
2.Systemboard
001-272-XXXSystemIRQ5failure1.DeviceonIRQ5
2.Systemboard
46ThinkCentreHardwareMaintenanceManual