Laptop User Manual
Table2.Numericerrorcodes(continued)
Symptomorerror
FRUoraction,insequence
2000:ThinkVantage
®
ActiveProtectionsensordiagnostics
failed.
Systemboard
2100:DetectionerroronHDD0(MainHDD)
1.Reseattheharddiskdrive.
2.Mainharddiskdrive
3.Systemboard
2101:DetectionerroronHDD1(UltrabayHDD)
1.Reseattheharddiskdrive.
2.Ultrabay
®
harddiskdrive
3.Systemboard
2102:DetectionerroronHDD2(MiniSATA)1.ReseattheMiniSATAdevice.
2.MiniSATAdevice
3.Systemboard
2110:ReaderroronHDD0(MainHDD)
1.Reseattheharddiskdrive.
2.Mainharddiskdrive
3.Systemboard
2111:ReaderroronHDD1(UltrabayHDD)
1.Reseattheharddiskdrive.
2.Ultrabayharddiskdrive
3.Systemboard
2112:ReaderroronHDD2(MiniSATA)1.ReseattheMiniSATAdevice.
2.MiniSATAdevice
3.Systemboard
2200:MachineTypeandSerialNumberareinvalid.Systemboard
2201:MachineUUIDisinvalid.
Systemboard
Errormessages
Table3.Errormessages
Symptomorerror
FRUoraction,insequence
Fanerror.1.Fan
2.Thermalgrease
3.Systemboard
Thermalsensingerror.
Systemboard
Thebatteryinstalledisnotsupportedbythissystem
andwillnotcharge.Pleasereplacethebatterywiththe
correctLenovobatteryforthissystem.PresstheESC
keytocontinue.
Replacethebattery.
Beepsymptoms
Table4.Beepsymptoms
Symptomorerror
FRUoraction,insequence
Fourcyclesoffourshortbeeps
Systemboard
Fiveshortbeeps,pause,andvemoreshortbeeps
Systemboard
Oneshortbeep,pause,threeshortbeeps,pause,three
moreshortbeeps,pause,andoneshortbeep
1.Memorymodule
2.Systemboard
Threeshortbeeps,pause,oneshortbeep,pause,one
moreshortbeep,pause,andthreeshortbeeps
RemovetheinstalledPCIdevices.
Chapter4.Relatedserviceinformation43