Specifications
Table Of Contents
- Safety information
- Chapter 1. General information
- Chapter 2. Server setup road map
- Chapter 3. Product overview
- Chapter 4. Turning on and turning off the server
- Chapter 5. Configuring the server
- Chapter 6. Installing, removing, or replacing hardware
- Guidelines
- Removing the server cover
- Removing and reinstalling the front bezel
- Removing and reinstalling the PCI card bracket assembly
- Installing, removing, or replacing hardware
- Installing or removing a memory module
- Installing or removing the Ethernet card
- Installing or removing the RAID card
- Installing or removing the ThinkServer RAID 500 Upgrade Key for Advanced RAID
- Installing or removing the ThinkServer RAID 700 Battery
- Installing or replacing an optical drive
- Installing or removing a non-hot-swap hard disk drive
- Installing or replacing an internal RDX drive
- Installing or replacing a 2.5-inch solid-state drive
- Installing or replacing a hot-swap hard disk drive
- Installing or replacing a hot-swap redundant power supply
- Replacing the power distribution board and cage assembly
- Replacing the power conversion board
- Replacing the hot-swap hard-disk-drive backplane
- Replacing the non-hot-swap power supply assembly
- Replacing the cover presence switch
- Replacing the front panel board assembly
- Replacing the front system fan 1
- Replacing the rear system fan
- Replacing the heat sink and fan assembly
- Replacing the microprocessor
- Replacing the system board battery
- Replacing the system board
- Completing the parts replacement
- Chapter 7. Troubleshooting and diagnostics
- Chapter 8. Getting information, help, and service
- Appendix A. Notices
- Trademarks
- Important notes
- Polyvinyl Chloride (PVC) cable and cord notice
- Recycling information
- Particulate contamination
- Important WEEE information
- Restriction of Hazardous Substances Directive (RoHS)
- German Ordinance for Work gloss statement
- Export classification notice
- Electronic emission notices
- Eurasian compliance mark
- Index

Thehot-swapredundantpowersupplyaddsasecondsourceofpowertotheserver.Whentheserveris
populatedwithtwohot-swapredundantpowersupplies,itcanwithstandapowerlossfromeitherpower
supply.Thishelpsyouavoidsignificantinterruptiontotheoperationoftheserverwhenapowersupplyfails.
Youcanreplacethefailinghot-swapredundantpowersupplywithoutturningofftheserver.
Someservermodelscomewithonlyonepowersupply.Youcanpurchaseahot-swapredundantpower
supplyoptionfromLenovo.
CAUTION:
Hazardousmovingparts.Keepfingersandotherbodypartsaway.
CAUTION:
Neverremovethecoveronapowersupplyoranypartthathasthefollowinglabelattached.
Hazardousvoltage,current,andenergylevelsarepresentinsideanycomponentthathasthislabel
attached.Therearenoserviceablepartsinsidethesecomponents.Ifyoususpectaproblemwith
oneoftheseparts,contactaservicetechnician.
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanother
computerforreference.
Notes:
•TomaintaintheEMIintegrityandcoolingoftheserver,installanewhot-swapredundantpowersupply
assoonasyouremovethefailingoneorcovertheotherbaywithashieldifyouuseonepowersupply
toprovidepower.
•Yourhot-swapredundantpowersupplymightlookslightlydifferentfromtheillustrationsinthistopic.
•Useanydocumentationthatcomeswiththenewhot-swapredundantpowersupplyandfollowthose
instructionsinadditiontotheinstructionsinthistopic.
Toinstallorreplaceahot-swapredundantpowersupply,dothefollowing:
Chapter6.Installing,removing,orreplacinghardware123