User Manual

Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17 136
13 Parameter reference
13.2 Basic parameters of the Controllers 3200 C/c300 and p300/p500
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C0056
C0057
C0058
C0064
C0070
Parameter | Name:
C0056 | Logbook: Index of last entry on CF
Data type: UNSIGNED_32
Index: 24519
d
= 5FC7
h
Number of the last entry on the SD memory card
Display range (min. value | unit | max. value)
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0057 | Logbook: Index of last entry
Data type: UNSIGNED_32
Index: 24518
d
= 5FC6
h
Number of the last entry in the logbook
Display range (min. value | unit | max. value)
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0058 | Logbook: Time of last entry
Data type: DATE
Index: 24517
d
= 5FC5
h
Time of the last entry in the logbook
Display range (min. value | unit | max. value)
(Local time
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0064 | Logbook: Time of last error entry
Data type: DATE
Index: 24511
d
= 5FBF
h
Entry of the last time error in the logbook
Display range (min. value | unit | max. value)
(Local time
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0070 | Ratio: Data/program memory
Data type: UNSIGNED_32
Index: 24505
d
= 5FB9
h
• A part of the available memory is provided to the current programs as main memory.
• The other part is available as object store for saving files in the RAM.
The percentage value indicated shows the ratio between object store (MemoryVirtualFilesAll) and total memory.
Setting range (min. value | unit | max. value) Lenze setting
0%2727 %
Read access Write access CINH PLC-STOP No transfer