During normal operation the Windows® CE functions are hidden on the controller. All controller
functions can be controlled via the Engineering PC.
For diagnostic purposes and maintenance activities you can use the standard functions of the
controller operating system Windows® CE.
You can access the Windows® CE functions
via the service mode if the controller is operated directly,
via a telnet connection with the corresponding administrator rights.
How to activate the user interface of Windows® CE on the controller:
1. Activate the service mode by keeping the <Shift> key pressed. There are two possibilities of
activating the service mode:
<Shift>+<F4> starts the Control panel. The entry can be made via the on-screen keyboard
or via an optionally connected keyboard.
When the green LED is blinking, you can start the Control panel with function key
<F1> on the monitor panel.
2. Start the Service command by double-click.
3. Activate the task bar by entering explorer in the command line box.
The task bar facilitates the navigation by providing the basic functions of Windows® CE:
Note!
In order to be able to use a telnet connection, you have to provide a telnet authorisation
to the corresponding Windows® CE user.