User guide

Table Of Contents
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05 159
8 Diagnostics & error management
8.7 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.7.3 Short overview (A-Z)
The table below contains all error messages of the controller operating system in alphabetical order.
Tip!
If you click the cross-reference in the first column, "Error number", you get to the detailed
description of the respective error message in the subsequent "Cause & possible remedies
"
chapter .
( 161)
Note!
For the sake of legibility, the Logbook and C165 display the error number with the follo-
wing syntax:
[Error type].[Error subject area no.].[.].[Error ID]
In this documentation, "xx", a wildcard, stands for the error type since it is configurable
for many error messages.
Error number Error message Response
(Lenze setting)
can be set in CAN Emergency
Error Code
xx.0125.00001
An01: AIN1_I < 4 mA Fault C598/1 0xF000
xx.0131.00006
CA06: CAN CRC error No response C592/1 0x8000
xx.0131.00007
CA07: CAN Bus Warn No response C592/3 0x8000
xx.0131.00008
CA08: CAN Bus Stopped No response C592/4 0x8000
xx.0131.00011
CA0b: CAN Bus Live Time No response C592/5 0x8130
xx.0131.00015
CA0F: CAN control word No response C594/2 0xF000
xx.0135.00001
CE1: CAN RPDO1 No response C593/1 0x8100
xx.0135.00002
CE2: CAN RPDO2 No response C593/2 0x8100
xx.0131.00000
CE4: CAN Bus Off No response C592/2 0x8000
xx.0145.00001
dF01: Internal error 01 Fault -
xx.0145.00002
dF02: Internal error 02 Fault -
xx.0145.00003
dF03: Internal error 03 Fault -
xx.0145.00004
dF04: Internal error 04 Fault -
xx.0145.00005
dF05: Internal error 05 Fault -
xx.0145.00006
dF06: Internal error 06 Fault -
xx.0145.00007
dF07: Internal error 07 Fault -
xx.0145.00008
dF08: Internal error 08 Fault -
xx.0145.00009
dF09: Internal error 09 Fault -
xx.0145.00010
dF10: Internal error 10 Fault -
xx.0400.00105
dH69: Adjustment data error Fault - 0x5530
xx.0123.00057
ID1: Motor data identification error WarningLocked - 0xF000
xx.0123.00015
LU: DC bus undervoltage Trouble C600/1 0x3100
xx.0123.00016
OC1: Power section - short circuit Fault - 0x2000
xx.0123.00017
OC2: Power section - earth fault Fault - 0x2000
xx.0119.00050
OC5: Ixt overload WarningLocked C604 0x2000
xx.0123.00105
OC6: I2xt motor overload WarningLocked C606 0x2000
xx.0119.00052
OC9: Ixt overload - shutdown limit Fault - 0x2000
xx.0123.00065
OC12: I2xt brake resistance overload Fault - 0xF000
xx.0119.00001 OH: Heatsink overtemperature Fault - 0x4000
xx.0123.00014
OU: DC bus overvoltage Trouble - 0x3100
xx.0144.00001
PS01: No memory module Warning - 0x6300
xx.0144.00002 PS02: Par. set invalid Fault - 0x6300