Instruction Manual
Mechanical installation
Standard devices in a power range of 0.25 ... 3 kW
Mounting i n ”cold plate” technique
5
105
EDS84ASC552 EN 9.1
StateLine, HighLine
8400GG105a
Fig. 5-12 Dimensions for mounting
d
1
d
2
d
3
d
4
c c
1
c
2
c
3
i j
11
j
21
[kW] [mm] [kg]
E84AVxxC2512xX0 0.25
10 10 85 80 12 6 6 90 0 >95 >95 1.3
E84AVxxC3712xX0 0.37
E84AVxxC3714xX0 0.37
8.5 12.5 110 105 12 6 6 90 0 >95 >95 1.5
E84AVxxC551xxX0 0.55
E84AVxxC751xxX0 0.75
E84AVxxC112xxX0 1.1
12.5 12.5 135 135 12 6 6 125 0 >95 >95 2.0
E84AVxxC152xxX0 1.5
E84AVxxC222xxX0 2.2
E84AVxxC2512xB0 0.25
10 10 85 80 12 6 6 90 0 >95 >95 1.4
E84AVxxC3712xB0 0.37
E84AVxxC3714xB0 0.37
8.5 12.5 110 105 12 6 6 90 0 >95 >95 1.6
E84AVxxC551xxB0 0.55
E84AVxxC751xxB0 0.75
E84AVxxC112xxB0 1.1
12.5 12.5 135 135 12 6 6 125 0 >95 >95 2.1
E84AVxxC152xxB0 1.5
E84AVxxC222xxB0 2.2