Instruction Manual

Electrical installation
Common control terminals
Important notes
6
210
EDS84ASC552 EN 9.1
Preparing the cable installation
The shields of the control cables are connected to the left shield lug of the front shield
sheet. F or this, proceed as shown in the illustration.
1. Release the holding screw of the shield s heet.
2. Bring the shield sheet into one of the two possible lock-in positions.
3. Tighten the holding screw to lock the shield sheet.
8400GG018
Fig. 6-25 Locate shield sheet in position