Instruction Manual
Braking operation
Braking o peration with external brake resistor
Operation at rated mains voltage 400 V
8
251
EDS84ASC552 EN 9.1
8.2.2 Operation at rated mains voltage 400 V
Switching threshold V
BRmax
: 725 V, adjustable
R
Bmin
[]
I
BRmax
[A]
P
BRmax
[kW]
I
BRd
[A]
P
Bd
[kW]
t
Z
[s]
t
on
[s]
t
fp
[s]
Type
E84AVxxx3714 390 1.9 1.3 1.9 1.3 - -
E84AVxxx5514 390 1.9 1.3 1.9 1.3 - -
E84AVxxx7514 390 1.9 1.3 1.9 1.3 - -
E84AVxxx1124 180 4.0 2.9 4.0 2.9 - -
E84AVxxx1524 180 4.0 2.9 4.0 2.9 - -
E84AVxxx2224 150 4.8 3.5 4.8 3.5 - -
E84AVxxx3024xxS 82 8.8 6.4 8.8 6.4 - -
E84AVxxx3024xx0 82 8.8 6.4 8.8 6.4 - -
E84AVxxx4024 47 15.4 11.2 13.0 9.4 - -
E84AVxxx5524 47 15.4 11.2 13.0 9.4 - -
E84AVxxx7524 27 26.9 19.5 26.9 19.5 - -
E84AVxxx1134 27 26.9 19.5 26.9 19.5 - -
E84AVxxx1534 18 40.3 29.2 40.3 29.2 - -
E84AVxxx1834 15 48.3 35.0 48.3 35.0 - -
E84AVxxx2234 15 48.3 35.0 48.3 35.0 - -
E84AVxxx3034 7.5 96.7 70.1 96.7 70.1 - -
E84AVxxx3734 7.5 96.7 70.1 96.7 70.1 - -
E84AVxxx4534 7.5 96.7 70.1 96.7 70.1 - -
R
Bmin
Minimum brake resistance, nominal value ±10 %
I
BRmax
Peak current
P
BRmax
Peak braking power
I
BRd
Continuous current RMS - important for the dimensioning of the cables
P
Bd
Continuous braking power
t
Z
Cycle time, periodic load change with running time and recovery time
t
on
Running time
t
Z
-t
on
Recovery time
t
fp
Maximum running time without initial load and compliance with t he recovery
time