Instruction Manual

Braking operation
Operation with spring-applied brake
Wiring
8
264
EDS84ASC552 EN 9.1
ƒ Integrated brake control for devices of the H ighLine/TopLine version
L1
L2
L3
N
PE
F10
BD2
U
L1
L3
PE
L2
-+
BD1
V
M
3~
E84AVHC... / E84AVTC...
~
24 VDC
1.5mm²
GBW
24B
PE
X107
"
"
BD1=+
BD2=-
}
"
X100
X105
+
+
E84HLC005
E84AVxC... Controller of the HighLine or TopLine version
F10 Cable protection in secondary circuit.
Observe the standards for cable protection and the safety instructions for the
installation according to UL o r UR when dimensioning the fuse!
HF-shield termination by large surface connection to PE.