Instruction Manual
Safety engineering
Technical data
10
282
EDS84ASC552 EN 9.1
Truth table
Safe input / channel Signalling
output
Controller
SIA SIB DO1/DO Description of device status Enable
001
”Safetorqueoff”activated
0
0 1 0 0
1 0 0 0
1 1 0 Drive active 1
Restriction of use