Instruction Manual

Technical data
Rated data
Operation at rated mains voltage 230 V
4
36
EDS84ASC552 EN 9.1
4.2.2 Operation at rated mains voltage 230 V
Basis of the data
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f[Hz]
1/N/PE AC 230 180-0%...264+0% 45-0%...65+0%
Mains current at I
aN
Apparent output power Motor power
with external
mains choke
without external
mains choke
U, V, W 4pol.ASM
Type I
LR
[A] I
LR
[A] S
aR
[kVA] P
aR
[kW]
E84AVxxx2512 3.0 3.4 0.6 0.25
E84AVxxx3712 4.2 5.0 0.9 0.37
E84AVxxx5512 5.0 5.3 1.1 0.55
E84AVxxx7512 7.0 8.0 1.4 0.75
E84AVxxx1122 9.9 12.0 2.0 1.1
E84AVxxx1522 11.4 13.7 2.5 1.5
E84AVxxx2222 16.4 21.8 3.4 2.2
Assignment of external mains chokes
Assignment
Type Mains choke required Mains choke
E84AVxxx2512 No
ELN1-0900H005
E84AVxxx3712 No
E84AVxxx5512 No
ELN1-0500H009
E84AVxxx7512 No
E84AVxxx1122 No
ELN1-0250H018
E84AVxxx1522 No
E84AVxxx2222 No