Owner manual

110
10.2 LECOM2 interface (option)
For more sophisticated applications, you can use a field bus
connecting interface. In the programming section, this interface is
called LECOM2. For the bus system Interbus-S the connecting
interface 2110 with the DRIVECOM profile is available. For the bus
system PROFIBUS the connecting module 2130 is also available
with DRIVECOM profile. The modules 2110 and 2130 are available
are options and can be integrated into the inverter (see also page
50).
10.3 LECOM codes
Some codes have a special meaning for the serial communication.
The codes C043, C068, C069, C161 to C168 cannot be read on the
dispaly of the device.
10.3.1Controller address
Under code C009 you enter the bus participant number for the
communication via interface. The addresses 1 to 99 can be
assigned, but "10", "20", ... "90" are not possible.
10.3.2Operating state
Under code C068, the operating state is displayed.
bit no. 15 14 13 12 11 10 9 8
Signal TRIP Feedback
= set-
value
I
max
Quick
stop
IMP Dir. of
rotation
Qmin Controller
enable
bit no.76543210
Signal Communication error Operating fault
10.3.3Controller state
Under code C069, the controller state is displayed.
bit no.76543210
Signal Ctrl.
enable
xxx RESET AUTO REMOTE PCHG C-ALARM B-ALARM
10.3.4Pole pair number
You must enter the pole pair number to calculate the speed.
Code Parameter Meaning
C092 1...6 Pole pair number