Owner manual
33
5.2.7 Frequency output 6⋅ f
d
If you want to display, for example, the output frequency or the
speed of the drive via a digital display device, you can use the
frequency output "6 times field frequency". As factory setting, this
function is assigned to terminal A4. This output is, like the other
digital outputs, isolated and can be supplied via terminals 39 and
59.
digital output
10k
2k7
X3 39 A4 59
X4
n
digital tacho
( Lenze type 322 )
+
-
supply
S2