Owner manual

37
6.1.1 Selection of the brake resistor
The following combinations ensure
- a maximum braking time of 15 seconds
- a maximum relative duty time of 10%.
The set continuous power of the inverter is the reference for the
combination.
Operation at rated power (factory setting)
Inverter type 8601 8602 8603 8604 8605
Resistor/ 370 370 240 180 180
Power/kW 0.15 0.15 0.2 0.3 0.3
Order number ERBM370R150W ERBM370R150W ERBM240R200W ERBD180R300W ERBD180R300W
Inverter type 8606 8607 8608 8609 8610
Resistor/ 100 100 68 47 33
Power/kW 0.6 0.6 0.8 1.2 2.0
Order number ERBD100R600W ERBD100R600W ERBD068R800W ERBD047R01K2 ERBD033R02K0
Inverter type 8611 8612 8613 8614 8615
Resistor/ 33 22 15 15 15
Power/kW 2.0 3.0 4.0 4.0 4.0
Order number ERBD033R02K0 ERBD022R03K0 ERBD015R04K0 ERBD015R04K0 ERBD015R04K0
Operation at increased power
Inverter type 8601 8602 8603 8604 8605
Resistor/ 370 240 180 180 180
Power/kW 0.15 0.2 0.3 0.3 0.3
Order number ERBM370R150W ERBM240R200W ERBD180R300W ERBD180R300W ERBD180R300W
Inverter type 8606 8607 8608 8609 8610
Resistor/ 100 100 47 33 33
Power/kW 0.6 0.6 1.2 2.0 2.0
Order number ERBD100R600W ERBD100R600W ERBD047R01K2 ERBD033R02K0 ERBD033R02K0
Inverter type 8611 8612 8613 8614 8615
Resistor/ 33 15 15 15 15
Power/kW 2.0 4.0 4.0 4.0 4.0
Order number ERBD033R02K0 ERBD015R04K0 ERBD015R04K0 ERBD015R04K0 ERBD015R04K0
Operation at maximum power
Inverter type 8601 8602 8603 8604 8605
Resistor/ 240 180 180 180 -
Power/kW 0.2 0.3 0.3 0.3 -
Order number ERBM240R200W ERBD180R300W ERBD180R300W ERBD180R300W -
Inverter type 8606 8607 8608 8609 8610
Resistor/ 100- 333333
Power/kW 0.6 - 2.0 2.0 2.0
Order number ERBD100R600W - ERBD033R02K0 ERBD033R02K0 ERBD033R03K0
Inverter type 8611 8612 8613 8614 8615
Resistor/ - 151515-
Power/kW - 4.0 4.0 4.0 -
Order number - ERBD015R04K0 ERBD015R04K0 ERBD015R04K0 -
A higher brake power can be obtained by using other resistors or
by connecting several resistors in parallel or in series. However, the
minimum resistance given on page 38 must be maintained!